Referenced Document - MCU13/0146
Report #S7186, Lot 10 (MCH 5387), Tropicana Rise, Castaways Beach QLD 4567
28 August 2013
Table 4 Risk Assessment Matrix
Hazard Likelihood Consequence Risk
1. Hillside slope failure: -
Lower than dwelling Possible Minor Medium
At dwelling site Unlikely Minor Low
Above dwelling site Rare Minor Very Low
2. Unsupported batters: -
Cut Likely Minor Moderate
Fill Likely Minor Moderate
The development should generally include works which result in acceptable risk levels to property after
completion of construction. In some cases, subject to appropriate monitoring and maintenance programs,
a tolerable risk may be accepted.
The Practice Note Guidelines for Landslide Risk Management (AGS (2007c)) indicate that the regulator (i.e.
Council) is the appropriate authority to set standards for risk levels but also suggests that, for most
development in existing urban areas, criteria based on Tolerable Risk levels are applicable because of the
trade-off between the risks, the benefit of development and the cost of risk mitigation. Definitions of
acceptable and tolerable risk as included in the Practice Note Guidelines for Landslide Risk Management
(AGS (2007c)) are as follows: -
Tolerable Risk – Risks within a range that society can live with so as to secure certain benefits. It
is a range of risk regarded as non-negligible and needing to be kept under review and reduced
further if practicable.
Areas initially of moderate or high risk level to property may be accepted for development subject to
detailed investigation to define hazards, provided that planning and treatment options are implemented to
reduce risks to acceptable levels.
Acceptable Risk – Risks which everyone affected is prepared to accept. Action to further reduce
such risk is usually not required unless reasonably practicable measures are available at low cost in
terms of money, time and effort.
Low to moderate risk levels are usually considered acceptable to regulators provided that the development
of the site be carried out in accordance with good engineering practice for hillside developments and with
the subsequent Section 6 of this report.
GeoConsulting Pty Ltd
1/8 Denna St, Maroochydore, QLD, 4558. Phone: 5443 6622, Fax: 5479 1899, Email: [email protected] 9|Page
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REFERENCED DOCUMENT - MCU13/0146Related documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.