Report #S7186, Lot 10 (MCH 5387), Tropicana Rise, Castaways Beach QLD 4567
28 August 2013




 6.0       CONSTRUCTION RECOMMENDATIONS

 6.1       Good Engineering Practice

Attached as APPENDIX C, are extracts from Practice Notes & Guidelines for Landslide Risk Management,
(AGC (2007c)), including: -
           “Some Guidelines for Hillside Construction”
           “Examples of Good Hillside Practice”
Recommendations and guidelines have been related to this allotment below.


 6.2       Site Clearing

Only clear the site where required for construction of the proposed residence, and retain as much of the
natural vegetation as possible. Exposed soils will be subject to runoff scour; hence ground cover
protection is required and tree / shrub species should be established downslope of the residential envelope.
It is envisaged the direct building surrounds will be landscaped. During the construction phase, silt fences
should be in place to control and retain runoff. Species should conform to the Foundation Maintenance
and Footing Performance: A Homeowner’s Guide, (CSIRO 2003), a copy of which is attached as APPENDIX
D.


 6.3       Earthworks

        6.3.1       General Earthworks
The proposed building area is to be stripped of all organic material and/or material that will inhibit
construction. Excessive earthworks proposed on this site may require an “Operational Works” permit,
which must be obtained from the Local Authority.

Some minor to moderate earthworks (approximately 1.0m cut and 1.0m fill) will be required in order to
create a series of level building platforms which step down the slope, as specified on the architectural
plans). The following details should be considered: -
           It is preferred that earthworks are prepared in accordance with the guidelines of AS3798.
           A positive drainage gradient is to be maintained over the building areas.
           Spoon drains to be installed at the toe of cut embankments
           Fill batters should grade at not less than 1:2½ (V:H).
           Cut batters that are not retained should grade at not less than 1:2 (V:H).
           Exposed surfaces should be vegetated to reduce the opportunity for runoff scour

        6.3.2       Filling outside the Residential Footprint & Driveway Areas
Placement of fill on the steep flanks is not recommended and other fill areas should preferably be retained.
Site preparation of filled areas will include stripping of topsoil and closely benching the exposed slope
prior to placement of fill in accordance with AS 3798. Fill areas should be prepared to support minimum


GeoConsulting Pty Ltd
1/8 Denna St, Maroochydore, QLD, 4558. Phone: 5443 6622, Fax: 5479 1899, Email: [email protected]   10 | P a g e

Used in these records

About this file

File size
2.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

REFERENCED DOCUMENT - MCU13_0146.pdf · 2.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.