GENERAL COMMITTEE MEETING AGENDA 16 DECEMBER 2019
Earthworks
9. Earthworks required on site must be carried out in accordance with Council’s Planning
Scheme Policy PSP5 Engineering Design Standards, so as not to cause the additional
ponding of water on any adjoining lands or concentrate or direct overland flow on to an
adjoining property.
Geotechnical Stability
10. All works must be carried out strictly in accordance with the geotechnical report prepared
by Core Consultants Pty Ltd and dated 24 September 2019, including the following
recommendations (which are the minimum specifications):
10.1. piles are to be a minimum of 10m deep;
10.2. pile arrangement number, arrangement and spacing and associated A frame
structure and capping beams are to be, as a minimum, in accordance with Drawing
Number P1001 entitled ‘A Frame for Slope Stabilisation General Arrangement’ and in
accordance with Figure B4 entitled ‘Case 4; Piles Support’;
10.3. grout columns are to be installed between the micro-piles to a minimum depth of 10m
to prevent all sand flow between the piles; and
10.4. a minimum of 56 piles are required with 50 required under the eastern side of the
pool.
11. All works associated with the construction of the pool are to be certified by a Registered
Professional Engineer of Queensland (RPEQ) to ensure compliance with the geotechnical
report prepared by Core Consultants Pty Ltd and dated 24 September 2019, and the
conditions of approval.
Coastal Protection
12. To protect the coastal dune system, a mix of native endemic coastal vegetation consisting
of ground covers, shrubs and trees must be planted for a width of 5m for the full length of
the seaward boundary in accordance with Council’s Planning Scheme Policy PSP3
Landscaping Plants and Guidelines. The planted vegetation must have a minimum pot
size of 200mm and must be planted at the following density:
a. trees must have a maximum spacing of 5m;
b. shrubs must have a maximum spacing of 2m; and
c. ground covers planted between the trees and shrub stems to provide a dense
coverage.
13. An access gate or like device allowing access to the beachfront area is not permitted to be
installed.
REPORT
On 20 December 2018, Council, at its Ordinary Meeting, resolved to refuse an application to
change an existing development approval for a house to facilitate the construction of a swimming
pool and an extension to a deck within the state Coastal Building Line at 42 Seaview Terrace,
Sunshine Beach.
The proposed works included 2 new in ground water tanks, approximately 48m2 of decking and a
13.4m x 4.4m swimming pool and a set of stairs seaward of the coastal building line.
Page 29 of 51