                                     the building's external materials and
                                     finishes and may incorporate solid
                                     translucent screens, shutters,
                                     perforated panels or trellises which
                                     have a maximum of 50% openings.

                                     Editor's note—refer to figure AP3-
                                     1B
PO21                                 AO21.1                                        Air conditioning compressor units
Mechanical plant, vehicle            Communal outdoor recreational                 will be located in the garage to
manoeuvring, utilities and           facilities including swimming pools,          each dwelling and will not be
communal outdoor recreation uses:    spas and sports courts are:                   visible or noticeably audible from
 a) do not have an adverse effect                                                  outside.
    on the amenity enjoyed by          a)   setback at least 12 metres
    users of adjacent or nearby             from the boundary of land in a
    premises through emission of            residential zone and screened
    noise, light, fumes or smoke;           by a 5 metre wide buffer
    and                                     densely planted with trees and
 b) do not cause unreasonable               shrubs including species from
    disturbance to local fauna              1 metre to 8 metres in height;
    through light or smoke                  or
    emissions.                         b)   located internally to the
                                            arrangement of buildings on
                                            the site; and
                                       c)   not used between the hours
                                            of 9:00pm and 6:30am the
                                            following day.

                                     AO21.2
                                     For a lit sports court:

                                       a)   the court is located at least 60
                                            metres from the external wall
                                            of an existing or
                                            approved dwelling on
                                            adjoining or nearby premises
                                            (as measured from the centre
                                            line of the court); and
                                       b)   the vertical illumination
                                            resulting from direct, reflected
                                            or other incidental light
                                            emanating from the site does
                                            not exceed 8 lux when
                                            measured at any point 1.5
                                            metres outside the boundary
                                            and at any level from ground
                                            level upward; and
                                       c)   any floodlighting is restricted
                                            to the types that give no
                                            upward component of light
                                            were mounted horizontally
                                            (i.e. a full cut off luminaire).

                                     AO21.3
                                     Mechanical plant is-

                                       a)   located at least 2 metres from
                                            the side or rear property
                                            boundaries;
                                       b)   where located at ground level,
                                            screened by fencing 1.5
                                            metres in height or
                                            dense vegetation of at least
                                            1.5 metres in width
                                            incorporating grouped trees
                                            and shrubs with a maximum


                               Material Change of Use – Multiple Dwelling (Code Assessment)

Log in to download the original (Planning Report - Code MCU - 25-27 Toolar St Tewantin.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.