levels. If above +50mv check
oxygen level in tank to ensure it is
<2mg/l check flow rate to ensure
there is a 2hr dwell time
Carbon Dioxide CO2 N/A 20mg/l Check maintenance log to Ensure
probe has been recalibrated to
manufacturers recommendations.
Check protein skimmer and MBBR
for correct air flow to ensure CO2
is being gassed off.
Dissolved Oxygen 4mg/l N/A When low set point triggered turn
on manual bottled oxygen to feed
oxygen into emergency diffusers in
grow tanks immediately. Check
oxygen generator for correct
operation. Check water flow is
sufficient in grow tank that has low
oxygen. Clean oxygen probe,
check membrane for damage and
check maintenance log to ensure
probe has been calibrated to
manufacturers recommendations.
Salinity 13ppt 22ppt Check storage tank to ensure
supply water is correct salinity then
adjust accordingly
Temperature 25C 33C Check heater/ chiller for correct
operation
6 Biosecurity
6.1 Animal source
Animals should be obtained from disease-free farms or sources only, after appropriate health
testing and disease-free certification by a reputable veterinary laboratory; disinfect eggs or
larvae where appropriate, quarantine (isolate) all animal introductions from the rest of the farm
for an appropriate period of time. The length of quarantine time depends on the species of
aquatic animal and potential disease or parasite. Contact DPI&F veterinary and extension
officers for advice.
b) Seek advice on appropriate preventative treatments for parasites to all introduced animals
while still in quarantine.
6.2 Hygiene
a) Seek advice on the disinfection of eggs or larvae prior to use.
b) Remove sick and dying animals as soon as possible and treat in a quarantine section or
dispose of appropriately, so there is no contamination of the farm animals or aquatic
environment.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 3 - Site Based Management.pdfRelated documentApplication case desk ↗
About this file
- File size
- 325 KB (small file)
- File type
No other editions are linked here.