Council archive · source document
09/1654 - Preliminary Building Works Assessable Against the Planning Scheme [As Published] · 172009.1654
DEPCASEY PROPOSED RENOVATION 12 PIPER ST e . cA BUILDING CODE OF USFRALIA, s AUSTRALIAN STANDARDS. L RELATIVE LEVEL LHD AUSTRALIAN HEIGHT OATUM ISSUE DESCRIPTION NATURAL GROUND LINE A CONCEPT DESIGN FLOOR SPACE RATIO CAVITY SLIDING DOR 5 WORKING DRAWINGS c MODIFIED WORKING ORAWINGS - SLAS. SD #LUM. SLIDING GLASS DOOR ALUM. SLIDING GLASS. ALUM. DOUBLE HUNG WINDOW ALUM. AWNING WINDOW ALUM. FIXED GLASS ‘MINDGW FIXED GLASS DOWNPIPE FLOOR WASTE. HOT WATER SYSTEM YACCUUM SYSTEM AIR CONDITIONING OVER HEAD CUPSO/-RD LOAD BEARING UNDER BENCH OVEN WALL OVEN so / DISHWASHER MICROWAVE WASHING MACHINE WALK-IN-ROBE BC 10 BE CONFIRMED GENERAL NOTES. “Do NoT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. IF IN DOUBT, ASK. - THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIOR RO COMMENCING WORKS OR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM 10 THE BUILDING CODE OF AUSTRALIA 2006, CURRENT AUSTRALIAN STANDARDS, BUILOING REGULATIONS AND TOWN PLANNING REQUIREMENTS, REPORT ANY DISCREPANCIES TO THIS OFFICE, ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF AUSTRALIAN AND THE AUSTRALIAN STANOAROS LISTED IN NOTE 4. AS 1286 - 1994 GLASS IN BUILDINGS - SELECTION AND INSTALLATION AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING AS 1GB4 - 1999 NATIONAL TIMBER FRAMING CODE AS 2049 - 1992 ROOF TILES AS 2080 - 1995 INSTALLATION OF ROOF THES AS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION ASINZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGS AS 3600 - 1994 CONCRETE STRUCTURES AS 3660 - 2004 BARRIERS FOR SUBTERRANEAN TERMITES: AS 3700 - 1996 MASONRY IN BUILDINGS AS 3740 - 1994 WATERPROOFING OF WET AREAS IN RESIOENTIAL BUILDINGS AS 3786 - 1993 SMOKE ALARMS AS 4055 - 1992 WIND LOADINGS FOR HOUSING AG 4100 - 1996 STEEL STRUCTURES THESE PLANS SHALL BE READ iN CONJUNCTION WITH ANY SOIL, STRUCTURAL AND CIVIL ENGINEERING COMPUTIONS AND DRAWINGS, ALL BUILOINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE WITH AS 3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX INDICATING TYPE OF BARRIER AND REQUIRED PERIODICAL INSPECTIONS. . . SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES - U) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR N) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE li} FULLY GLAZED DOORS ~ iv] SHOWER SCREENS v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL vi} WINDOW SIZES AKE NOMINAL ONLY, ACTUAL SIZES WILL YARY WITH MANUFACTURER, AND ARE 10 BE VERIFIED WITH SAME. FLASHING ALL ROUND. . STORMWATER TO BE TAKEN TO ON SITE STORAGE OF PROVIDED, THEN THE LEGAL POINT OF DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY. TILEO DECKS-OVER LIVABLE AREAS ARE TO BE. IN THE FOLLOWING ORDER OVER THE FLOOR JOISTS : 19mm COMPRESSED FIBRE CEMENT ‘SHEET, WiTK ONE LAYER OF PARCHEM EMERPROOF 750 WITH A SECOND LAYER OF SAND ‘SEED WITH A DFT OF 1300 MICRON, INSTALLED TO MANUF. SPECIFICATIONS, AND FLOOR TILES OVER, ALL CORNERS 10 HAVE 20mm MASTIC SEALANT UNDER THE PARCHEM EMERPROOF 750. os FOOTINGS ARE TO BE WHOLLY WITHIN TITLE BOUNDARIES AND ARE NOT TO. ENCROACH EASEMENTS. IT IS RECOMMENDED THAT WHERE BUILOINGS ARE- 40 BE LOCATED IN CLOSE PROXIMITY OF BOUNDARIES, A CHECK SURVEY BE CONDUCTED BY A LICENSED SURVEYOR. ALL STEELWORK iN MASONRY TO BE HOT DIP GALVANISED. ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740, SPLASH BACKS. SHALL BE IMPERYIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE WALL. PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND WITHIN 300mm OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS. STEEL * SUB-FLOOR VENTILATION. MINIMUM 740Ommisq FOR EXTERNAL WALLS. AND 15COmm/sq FOR INTERNAL WALLS BELOW BEARER. THERMAL INSULATION 70 BE PROVIDED TO ACHIEVE MINIMUM REQUIREMENTS AS SPECIFIED BY LICENSED ASSESSOR. STAIR REQUIREMENTS : MIN. TREAD 240mm, MIN. RISER 1iSmm, MAX. RISER 190mm, SPACE BETWEEN OPEN TREADS MAX. 125mm, TREADS TO BE NON SLIP SURFACE. BALUSTRADES : MIN. 10O0mm ABOVE LANDINGS WITH MAX. OPENING OF 425mm AND §N ACCORDANCE WITH BCA 3.9.2 . FOR STAINLESS STEEL BALUSTRADE, REFER 10 Table 3.9.2.1 (WIRE BALUSTRADE CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLE DEFLECTION) OF THE BCA. THE BUILDER SHALL TAKE ALt STEPS NECESSARY TO ENSURE THE STABILITY OF EXISTING AND NEW STRUCTURES THROUGH-OUT CONSTRUCTION. . @ _DENOTES LOCATION OF SMOKE DETECTORS (refer electrical layout. plans), JO BE HARD WIRED WITH EMERGENCY BACK-UP AND COMPLY WITH AS . 3786. PROVIDE-LIFT OFF HINGES, OPEN OUT DOOR OR MIN 1200mm CLEARANCE «FROM DOOR TO PAN IN WATER CLOSETS. EXHAUST-FANS FROM SANITARY COMPARTMENTS ARE TO BE DUCTED EXTERNALLY OR TO A VENTED ROOF SPACE IN COMPLIANCE WITH AS 1668.2 THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS, STATUTORY REQUIREMENTS, BUILOING PRACTICE OR CONTRACTUAL OBLIGATIONS. THESE PLANS ARE PROTECTED BY COPY RIGHT AND ARE THE PROPERTY OF THE AUTHOR. platinum veorerty ggour building designers association of queensland inc. IMAGE + DESIGN BUILDING DESIGHS PROPOSED RENOVATION T2PUPER ST PEREGIAN BEACH SOOM APOIO pe Het ANOLE eS ote COAT *
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1654 - Preliminary Building Works Assessable Against the Planning Scheme [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.