Council archive · source document
Appendix E - Structural Engineering Drawings (Issue 1 - Dated 07-02-2023) · EXE23/0035
EXISTING RAFTERS
8mm WEB STIFFENER TO HAVE DOUBLE EXISTING RAFTERS EXISTING RAFTERS
FRAMING ANCHORS. 600
EITHER SIDE OF WEB
5.0 C.F.W. EXISTING RAFTERS
TO HAVE DOUBLE
EXISTING POLE FRAMING ANCHORS.
PLATE TO BE BOLTED
TO NEW STEEL ROOF
BEAM, M12-600 400
BEARING
EXISTING POLE ELONGATED 8mm THK
WALL PLATE TO BE BOLTED 8mm THK WEB CLEAT @ THIRD POINTS.
REINFORCEMENT TO NEW STEEL ROOF STIFFENERS 4/M12 BOLTS.
RB1-UB AS SPECIFIED BEAM, M12-600
RB1-UB RB1-UB
40Mpa NON
SHRINK GROUT
4/M16 BOLTS WITH LEVELING
NUTS. 400mm CAST IN BOLT
WITH 50 COG
SECTION A SECTION B
SCALE A1 - 1:10 S3.01 SCALE A1 - 1:10 S3.01
EXISTING 190 BLOCK Check all dimensions before commencement of work.
SCALE A3 - 1:20 SCALE A3 - 1:20
WORK TO BE CORE Check Site boundary dimensions from the Title plans.
2/N12 VERTICAL BAR FILLED AND REINFORCED. Check Building Boundary clearances by set out.
PLACED AT OPENING. N12-400 VERTICAL BARS Notwithstanding the information supplied on this drawing, the
EXISTING UPPER
(one each pot) location, depth and extent of underground or overhead services
FLOOR LEVEL
are to be confirmed and protected on site by the contractor prior
to commencement of works.
1 07.02.2023 FOR CONSTRUCTION MS
P1 22.12.2022 PRELIMINARY MS
Issue Date Description By
Drawing title -
EPOXY GROUTED SPECIFICATIONS:
ALL BOLTS AND DOWEL BARS TO BE GROUTED IN USING ROOF FRAMING DETAILS
RAMSET CHEMSET REO 502 PLUS AND INSTALLED AS
N12
N12
N12
PER MANUFACTURERS SPECIFICATION.
Project -
PROPOSED DECK
DOWN STAIRS EXISTING 190 BLOCK
WORK TO BE CORE
EXTENSION
DOOR OPENING
FILLED AND REINFORCED.
N12-400 VERTICAL BARS
Client -
Paul Cooper Homes
CUT FRONT FACE OF
BTM COURSES FOR
ANCHORING ACCESS.
Site -
2N12 x 500(L) STARTER BARS
EPOXY GROUTED 100mm INTO 24 Attunga Heights,
EXISTING SLAB
Noosa Heads
LAP
400
EXISTING LOWER
FLOOR LEVEL
Consulting Civil &
EMB'T
Min.
100
Structural Engineers
Project Management
ASSOCIATES PTY LTD
& Planning
UB / BLOCK WORK CONNECTION 124 DUPORTH AVENUE
PO BOX 16 MAROOCHYDORE QLD 4558
E-MAIL: [email protected]
DETAIL 1 Ph (07) 5443 7777 Fax (07) 5443 7577
SCALE A1 - 1:10 Approved:
S3.01
SCALE A3 - 1:20
KEVIN COVEY BEng, CPEng, MIEAust, MSPEPNG, RPEQ1823
CHRIS CAMP BEng(Hons), MIEAust, RPEQ4944
Checked : MC Design : SC Drawn : MS
Scales : AS SHOWN
Document Stage : CONSTRUCTION
Project : 223315 Sheet No. S3.02
Digital Ref : 223315 - STRUC Issue : 1
This document is copyright and shall not be copied without written
approval, nor shall it be used except for the development and the
site specified.
c:\12dS\data\12DSERVER\223315_2620\DWG Covey\Struc\Uncontrolled\223315 - STRUC.dwg Plot 08 Feb, 2023 - 08:34
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Structural Engineering Drawings (Issue 1 - Dated 07-02-2023).pdfRelated documentApplication case desk ↗
About this file
- File size
- 360 KB (small file)
- File type
No other editions are linked here.