Skip to the record
Mmm.. taste the original NoosaWatch™

Council archive · source document

05. Town Planning Report · MCU10/2127

From the archive MCU10/2127 Development Application part 2 of 2 Plans 5 Morwong Drive Noosa Heads. File date in the archive: 2010-12-20 09:49.

of 385

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (41.9 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

                         SPECIFIC OUTCOMES                                       PROBABLE SOLUTIONS                                   COMPLIANCE
                     exceed 40%;
          d)         for the Attached Housing Zone does not
                     exceed 40%; or
          e)         for the Visitor Mixed Use Zone does not
                     exceed 45%;
 O11      For Multiple Housing Type 2 buildings have a             S11.1   No solution provided.                            Not applicable.
          maximum plot ratio of 0.45:1.                                                                                     The proposed development does not
                                                                                                                            include Multiple Housing Type 2
                                                                                                                            buildings
 O12      For Multiple housing Type 3 or 4, Visitor                S12.1   No solution provided.                            Not Applicable
          accommodation Type 4 and the accommodation                                                                        The proposed development does not
          unit component of an Entertainment and dining                                                                     alter the gross floor area of the
          business Type 3 (hotel)—the maximum a gross                                                                       dwellings  within   the   existing,
          floor area is equivalent to the maximum allowable                                                                 approved resort development.
          population in persons multiplied by 40m2.
 O13      For the Visitor Mixed Use Zone, the maximum gross        S13.1   No solution provided.                            Not applicable.
          floor area equals the allowable population in persons                                                             The proposed development is not
          multiplied by 40m2, provided that the gross floor area                                                            situated in the Visitor Mixed Use
          does not exceed 13,600m2                                                                                          Zone.
 O14      For the Neighbourhood Centre Zone and the Business       S13.1   No solution provided.                            Not applicable.
          Centre Zone, the maximum plot ratio does not exceed                                                               The proposed development is not
          –                                                                                                                 situated in the Visitor Mixed Use
          a)      0.8:1 for the first 2,000m2 of site area; plus                                                            Zone.
          b)      0.3:1 for the balance of the site area in
                  excess of 2,000m2.
 Roof Form
 O15      Roof forms—                                              S15.1   The main roof of the building has a roof pitch   Not Applicable
          a)      contribute positively to the local skyline;              no less than 5 degrees and has minimum           The proposed development does not
          b)      complement the character of the locality;                600mm eaves to at least 75% of the               alter the roof form of the existing,
                                                                           perimeter of the building;                       approved resort development or
          c)      use soft and articulated, pitched, skillion or
                  curved roof forms;                                       AND                                              include roof top terraces.
          d)      avoid low pitched (eg. less than 5 degrees)      S15.2   Buildings and structures do not include roof
                  or box profiles/parapets; and                            top terraces.
          e)      do not create opportunities for residents to
                  overlook the private open space areas of
                  neighbouring properties.




HUMPHREYS REYNOLDS PERKINS PLANNING CONSULTANTS
20-Dec-10 - 10BR087.R01.010.docx

Used in these records

About this file

File size
41.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

05. Town Planning Report.pdf · 41.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.