SPECIFIC OUTCOMES PROBABLE SOLUTIONS COMPLIANCE
vehicles. attached to the Negotiated Decision Notice
of Noosa Shire Council dated 19 April 2007.
Basement drainage
O9 Development is designed to minimise S9.1 Enclosed car parking and manoeuvring Not Applicable
noise carrying between dwelling units areas are constructed at a level that permits The proposed development does not alter
or accommodation units by locating the parking area to drain from the site by the design and location of the existing car
noise sensitive spaces such as gravity means, without the need for parking areas.
bedrooms away from noise generating mechanical pumping.
areas of the development, such as
carparking areas or mechanic plant
and equipment or recreational
facilities.
Separation of incompatible uses
O10 Development is designed to minimise S10.1 Bedroom windows are at least 3m away Not Applicable
noise carrying between dwelling units from shared driveways or carparking areas The proposed development does not alter
or accommodation units by locating of adjacent dwelling units or accommodation the location of bedroom windows within the
noise sensitive spaces such as units. existing, approved resort development.
bedrooms away from noise generating
areas of the development, such as
carparking areas or mechanic plant
and equipment or recreational
facilities.
Mechanical plant & equipment
O11 Mechanical plant and equipment S11.1 Mechanical plant and equipment, including Not Applicable
associated with Residential Uses are pool and spa pumps, pool heaters, air- The proposed development does not alter
designed and located so as not have conditioning units and refrigeration units the location of the mechanical plant and
an adverse impact on the visual are— equipment installed within the existing,
amenity of the site or surrounding a) where located at ground level, approved resort development.
areas. screened by fencing 1.5m in height
or dense vegetation of at least
1.5m in width incorporating
grouped trees and shrubs with
maximum separation distance of
1m measured from the centre of
the plant; and
b) for Multiple Housing Type 2, 3 &
4 are visually integrated into the
line and plane of the building and
roof design and do not project
beyond the height or width of the
HUMPHREYS REYNOLDS PERKINS PLANNING CONSULTANTS
20-Dec-10 - 10BR087.R01.010.docx
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
05. Town Planning Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 41.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.