Original source · versioned page text
Attachment 11- Code Compliance Report
Compliance
Performance Outcome Acceptable Outcomes Response
//NA
Major Infrastructure
PO5 AO5.1 Complies with AO5.1
Development is sufficiently separated from Buildings and structures are not constructed under The proposed development is not located under
infrastructure including electricity infrastructure and overhead electricity transmission lines, or within overhead electricity lines or within easements.
substations to minimise the likelihood of nuisance or easements.
complaint.
AO5.2 Not Applicable
Development adjacent to or within 50 metres of a The proposed development is not located adjacent
substation, major electricity infrastructure or major to or within 50 metres of a substation, major
utility incorporates noise attenuation measures such NA electricity infrastructure or a major utility.
that noise levels do not exceed 5db(A) above
background noise level internal to buildings
measured in accordance with AS1055.
AO5.3 Not Applicable
Where adjoining substations, major electricity The proposed development is not located adjacent
infrastructure or major utilities, buildings are NA to of a substation, major electricity infrastructure or
orientated so that the majority of windows and doors a major utility.
face away from the infrastructure.
Landscaping
Ground floor AO6 Complies with AO6
PO6 Ground floor spaces have a minimum ceiling height The development ensures that ground floor spaces,
Ground floor spaces and ceiling heights are flexible to of 3.5 metres to allow flexibility of use (for example; excluding residential uses, are to have a ceiling
cater for a range of business activities. adaptation for shop, restaurant or office uses) height greater than 3.5metres, allowing for the
flexible catering of a range of business activities.
Please refer to Appendix A – Architectural Plans for
further detailed design.
Outdoor areas AO7 Complies with AO7
PO7 Outdoor areas and roof top areas used for business Outdoor areas are located and designed to ensure
Outdoor areas, including balconies and rooftops, activities are located away from sensitive land uses that the residential apartments are not unduly
used for business activities are located, designed and and are generally oriented towards the street. impacted by operations of the business activities.
The outdoor areas are focussed around the Civic
spine, activating the space and avoiding conflicts
Code Compliance Statements Page 66 of 136