160105 NSC Change to MCU Approval 111016 · MCU13/0251
Attached to the e-mail Request for change to approval MCU13/0251.03.
MCU13/0251.01
Community Management Statement
9. Any proposed Community Management Statement required for the development
pursuant to the Body Corporate and Community Management Act 1997 must be
submitted to Council for endorsement at the same time as submission of the Building
Format Plan (or similar) to Council for compliance assessment. All clauses and by-laws
of the proposed Community Management Statement must accord with the requirements
of this Decision Notice.
Fire Management
10. The development must be carried out in accordance with the recommendations of a
Bushfire Management Plan prepared by a suitably qualified person and an approval for
Operational Works.
11. Certification must be submitted from a suitably qualified person which certifies that the
recommendations of a Bushfire Management Plan approved by Council have been
incorporated into the development.
12. A copy of the Bushfire Management Plan approved by Council must be provided to the
nearest fire, ambulance and police station.
Koala Management
13. The development shall be carried out in accordance with the management measures
recommended in the Koala Habitat Management Report Solutions Report dated June
2010.
Bicycle Parking & End of Trip Facilities
14. Secure bicycle racks shall be provided on site to accommodate a minimum of 18
bicycles. The cycle parking rack is to be made available for customers and staff at all
times during business hours.
15. End of trip facilities shall be provided for staff and shall include a minimum of 4 lockers
and a minimum of 1 shower cubicle.
Acoustic Report
16. An acoustic report prepared by a suitably qualified person is to be submitted and
approved by council prior to the issue of the Decision Notice for Operational Works. The
acoustic report is to address all potential noise sources from the proposed development
and demonstrate that –
• mechanical equipment such as ventilation, air conditioning, refrigeration, fans,
plant rooms, refuse compactors and pumps etc. and
• vehicle movements from waste collection activities and delivery of goods
(including refrigerated vehicles, engine noise, fork lifts, compactors etc.) to the
service yard and dock area
will not cause an environmental nuisance to the future residential uses on the
balance of the site and the existing nearest residential areas when measured at
either the residential boundary or outside the most exposed part of an affected
building, whichever is the closest to the equipment. Noise emissions are to
comply with the noise requirements under the Environmental Protection Act 1994.
17. The acoustic report shall include the location of any plant and associated equipment,
predicted noise levels and a description of acoustic enclosures and screenings including
an acoustic screen along the western boundary to mitigate intrusive noise from delivery
and waste vehicles and associated activities.
Page 3 of 16
Document Set ID: 20182356
Version: 1, Version Date: 11/10/2016
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
160105 NSC Change to MCU Approval 111016.pdfRelated documentApplication case desk ↗
About this file
- File size
- 148 KB (small file)
- File type
No other editions are linked here.