Council archive · source document
Attachment 1 - Op Works Negotiated Decision Notice · OPW11/0335
Attached to the e-mail OPW11/0335 Request to Extend Relevant Period - 'Essence of Peregian' Operational Works.
23:
M FOHDQLQJ DQG RU UHILQLVKLQJ RI DOO H[WHUQDO VXUIDFHV LQFOXGLQJ SURPSWUHPRYDO RI
JUDIILWL
:DWHU6XSSO\DQG6HZHUDJH
8QLW\ZDWHUPXVWEHDGYLVHGLQZULWLQJRIWKHFRQWUDFWRU VQDPHDQGWKHSURSRVHGGDWHRI
FRPPHQFHPHQWRIFRQVWUXFWLRQ$PLQLPXPRIILYHGD\VQRWLFHLVUHTXLUHGWRHQDEOH
LQVSHFWLRQVWREHDUUDQJHGLQFOXGLQJDSUHVWDUWPHHWLQJRQVLWH3KRQH8QLW\ZDWHU
3LSHOD\HUDFFUHGLWDWLRQPXVWEHSURYLGHGDWWKH3UHVWDUWPHHWLQJLQFOXGLQJ³&HQWXU\3OXV´
DFFUHGLWDWLRQIRU',&/³3LSHOLQH,QVWDOODWLRQ´IRU39&DQG³(OHFWURIXVLRQ%XWW:HOGLQJ´IRU
3RO\HWK\OHQH3LSH
7KHH[LVWLQJGZHOOLQJORFDWHGZLWKLQWKH/RW63PXVWEHFRQQHFWHGWRWKHQHZ
VHZHUSURSHUW\FRQQHFWLRQSULRUWRWKHFDSSLQJDQGUHPRYDORIWKHH[LVWLQJVHZHUPDLQ
:DWHUPHWHUVPXVWEHLQVWDOOHGWRWKHGHYHORSPHQWLQDFFRUGDQFHZLWK8QLW\ZDWHU
UHTXLUHPHQWVDQGVWDQGDUGGUDZLQJV6&:DQG
(OHFWULFDOSLOODUPXVWEHORFDWHGRQDOWHUQDWLYHERXQGDU\WRZDWHUPHWHUV
$PLQLPXPKRUL]RQWDOFOHDUDQFHRIPHWUHPXVWEHPDLQWDLQHGEHWZHHQVWRUPZDWHU
SLSHVJUHDWHUWKDQPPGLDPHWHUDQG8QLW\ZDWHUZDWHUVXSSO\RUVHZHUDJH
LQIUDVWUXFWXUH
6WRUPZDWHUUHWHQWLRQV\VWHPVDQGJURVVSROOXWDQWWUDSVPXVWPDLQWDLQDPLQLPXPRI
PHWUHVKRUL]RQWDOFOHDUDQFHIURPDVHZHUDJHPDLQRUVHZHUKRXVHFRQQHFWLRQSRLQW
$PLQLPXPRIPHWUHVVHSDUDWLRQPXVWEHPDLQWDLQHGEHWZHHQWKHRXWHUPRVWHGJHRI
VHZHUDFFHVVFKDPEHUVRUVHZHUDJHPDLQVDQGWKHSURSHUW\ERXQGDU\
$PHWUHZLGHHDVHPHQWPXVWEHSURYLGHGRYHU8QLW\ZDWHUVHZHUVZLWKLQWKH
GHYHORSPHQWVLWH$PHWUHZLGHHDVHPHQWLVUHTXLUHGRYHUVHZHUVJUHDWHUWKDQ
PHWUHVGHHS(DVHPHQWVPXVWEHFHQWUDOO\ORFDWHGRYHUWKHPDLQ)RUVHZHUVRQVLGH
ERXQGDU\DOLJQPHQWVHDVHPHQWVPD\EHSDUWLDOO\ORFDWHGZLWKLQQHLJKERULQJSURSHUWLHV
3URSRVHGWUHHSODQWLQJVPXVWPDLQWDLQDPLQLPXPKRUL]RQWDOFOHDUDQFHRIPHWUHIURP
8QLW\ZDWHUZDWHUPDLQVDQGPHWUHVIURP8QLW\ZDWHUVHZHUDJHPDLQV/DQGVFDSLQJ
SODQWVZLWKLQWKHVHFOHDUDQFHVPXVWEHORZJURZLQJZKHQPDWXUHDQGVXLWDEOHDSSURYHG
YDULHWLHV
'XULQJWKHPDLQWHQDQFHSHULRGWKHDSSOLFDQWPXVWFDUU\RXWQHFHVVDU\UHSDLUVWRGHIHFWV
DQGRUGDPDJHRIURDGZRUNVGUDLQDJHDQGDVVRFLDWHGZRUNZDWHUVXSSO\DQGVHZHUDJH
UHWLFXODWLRQDQGSXPSVWDWLRQVDQGDVVRFLDWHGHTXLSPHQW7KHVHUHSDLUVLQFOXGHGDPDJH
DQGRUDOWHUDWLRQVFDXVHGE\WKLUGSDUWLHVFDUU\LQJRXWZRUNVZLWKLQWKHGHYHORSPHQW
&RQVWUXFWLRQZRUNVXQGHUWDNHQLQWKHYLFLQLW\RI8QLW\ZDWHU¶VH[LVWLQJZDWHUVXSSO\RU
VHZHUDJHLQIUDVWUXFWXUHPXVWQRWDGYHUVHO\DIIHFWWKHLQWHJULW\RIWKHLQIUDVWUXFWXUH$OO
FRVWVDVVRFLDWHGZLWKUHSDLUUHSODFHPHQWRUDOWHUDWLRQWRH[LVWLQJLQIUDVWUXFWXUHPXVWEH
PHWE\WKHDSSOLFDQW
3ULRUWRWKHFRPPHQFHPHQWRIWKHXVH$V&RQVWUXFWHGGUDZLQJVVKDOOEHORGJHGLQERWK
KDUGFRS\DQG$'$&GLJLWDOIRUPDWLQ*'$=RQHFRRUGLQDWHYDOXHV$VFRQVWUXFWHG
GUDZLQJVZLOOEHUHTXLUHGSULRUWRZRUNVEHLQJDFFHSWHG2Q0DLQWHQDQFH 7KH*'$FR
RUGLQDWHVDQG$+'OHYHOVRIDOOSHUPDQHQWVXUYH\PDUNVLQVWDOOHGVKDOOEHSURYLGHG 7KH
VXUYH\HGORFDWLRQPHWHUQXPEHUVDQGUHDGLQJVRIZDWHUPHWHUVLQVWDOOHGE\WKHGHYHORSHU
PXVWEHLQFOXGHGLQWKHDV FRQVWUXFWHGLQIRUPDWLRQ
$ZDWHUPHWHUUHFRUGVKHHWPXVWEHFRPSOHWHGDQGVXEPLWWHGWR8QLW\ZDWHU SULRUWRZRUNV
EHLQJDFFHSWHGRQPDLQWHQDQFH
8SRQFRPSOHWLRQRIWKHZRUNVDQGSULRU WRWKHFRPPHQFHPHQWRIWKHXVHDFHUWLILFDWHPXVW
EHLVVXHGE\D53(4FHUWLI\LQJWKDWWKHZRUNVKDYHEHHQFRQVWUXFWHGLQDFFRUGDQFHZLWK
8QLW\ZDWHU VWDQGDUGVDQGLQFRPSOLDQFHZLWKWKHDSSURYHGSODQVDQGVSHFLILFDWLRQV7KH
ZRUNVPXVWEHVXSHUYLVHGE\WKH(QJLQHHULQDSODQQHGDQGWLPHO\PDQQHUWRHQVXUHWKH
LQWHJULW\RIWKHFHUWLILFDWLRQLVXSKHOG
)0V 3DJH RI
[OCR of page images]
OPW 11/0335
j. cleaning and / or re-finishing of all external surfaces including prompt removal of
graffiti
Water Supply and Sewerage
76.
TT.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
Unitywater must be advised in writing of the contractor's name and the proposed date of
commencement of construction. A minimum of five days notice is required to enable
inspections to be arranged, including a pre-start meeting on site. Phone Unitywater: 07
5409 3870
Pipe layer accreditation must be provided at the Pre-start meeting including “Century Plus”
accreditation for DICL, “Pipeline Installation” for PVC and “Electrofusion/Butt Welding’ for
Polyethylene Pipe
The existing dwelling located within the Lot 51 SP156203 must be connected to the new
sewer property connection prior to the capping and removal of the existing sewer main.
Water meters must be installed to the development in accordance with Unitywater
requirements and standard drawings SCW350, 355 and 360
Electrical pillar must be located on alternative boundary to water meters.
A minimum horizontal clearance of 1.0 metre must be maintained between stormwater
pipes greater than 225mm diameter and Unitywater water supply or sewerage
infrastructure
Stormwater retention systems and gross pollutant traps must maintain a minimum of 1.5
metres horizontal clearance from a sewerage main or sewer house connection point
A minimum of 0.5 metres separation must be maintained between the outermost edge of
sewer access chambers or sewerage mains and the property boundary
A 3.0 metre wide easement must be provided over Unitywater sewers within the
development site. A 4.0 metre wide easement is required over sewers greater than 3.0
metres deep. Easements must be centrally located over the main. For sewers on side
boundary alignments easements may be partially located within neighboring properties
Proposed tree plantings must maintain a minimum horizontal clearance of 1.0 metre from
Unitywater water mains and 1.5 metres from Unitywater sewerage mains. Landscaping
plants within these clearances must be low growing when mature and suitable approved
varieties
During the maintenance period the applicant must carry out necessary repairs to: defects
and/or damage of road works; drainage and associated work; water supply and sewerage
reticulation and pump stations and associated equipment. These repairs include damage
and/or alterations caused by third parties carrying out works within the development
Construction works undertaken in the vicinity of Unitywater’s existing water supply or
sewerage infrastructure must not adversely affect the integrity of the infrastructure. All
costs associated with repair, replacement or alteration to existing infrastructure must be
met by the applicant
Prior to the commencement of the use As Constructed drawings shall be lodged in both
hardcopy and ADAC digital format in GDA94 Zone 56 coordinate values. As constructed
drawings will be required prior to works being accepted On Maintenance. The GDA co-
ordinates and AHD levels of all permanent survey marks installed shall be provided. The
surveyed location, meter numbers and readings of water meters installed by the developer
must be included in the as - constructed information
A water meter record sheet must be completed and submitted to Unitywater prior to works
being accepted on-maintenance
Upon completion of the works and prior to the commencement of the use a certificate must
be issued by a RPEQ certifying that the works have been constructed in accordance with
Unitywater standards, and in compliance with the approved plans and specifications. The
works must be supervised by the Engineer in a planned and timely manner to ensure the
integrity of the certification is upheld
FM1509s/2-13/04/2011 Page 15 of 24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment 1 - Op Works Negotiated Decision Notice.pdfRelated documentApplication case desk ↗
About this file
- File size
- 253 KB (small file)
- File type
No other editions are linked here.