Original source · versioned page text
Attachment B - Code Compliance Assessment.pdf
Performance Outcomes Acceptable Outcomes Planning Comment
Editor’s Note—The Plumbing and Drainage
Act 2003 sets out requirements for
wastewater management.
PO16 AO16 N/A
On-site effluent treatment and disposal An onsite effluent system and disposal No onsite effluent system is proposed as
systems are designed, constructed and area is: part of this development.
managed to not compromise the (a) not located on a slope greater than
environmental values of waters and water 1 in (10%);
quality objectives. (b) not located at or below the 1%
annual exceedance probability (AEP
flood event);
(c) not located within a riparian buffer
area mapped on a Biodiversity,
Waterways and Wetlands Overlay
Map; and
(d) setback 400 metres minimum from
the full supply level of Lake
Macdonald.
Editor’s Note—The Plumbing and Drainage
Act 2003 sets out requirements for on-site
effluent treatment and disposal. The
Queensland Plumbing and Wastewater Code
and associated guidelines are used to
confirm the suitability of each site to
accommodate an on-site sewerage facility; or
where a centrally located group collection
jrey.au | (07) 3106 3221 | [email protected]