GMA Certification Group Pty Ltd

T/A Geoff Mitchell & Associates ACN 104 855 110
BUILDING SURVEYORS

CERTIFICATION GROUP PTY LTO.

SUNSHINE COAST OFFICE
CLIENT: MEGAN WILLIAM

 

PHONE 07 5449 0383
FAX 07 5449 0483
SITE ADDRESS: LOT 8 EUGELLA DRIVE Teale Avene

 

TEWANTIN QLD 4565
POSTAL
SUBURB: BLACK MOUNTAIN P/CODE: PO Box 1452

NOOSAVILLE BC QLD 4566

E-Mail

RPD: Lot: 8 RP/SP: [email protected]

= —_—_—_—_—_—_—_—_—_— Web
www.geoffmitchell,com.au

Site Bushfire Attack Assessment

1.0 Introduction

The assessment of the proposed site is carried out to determine the category of bushfire attack in
accordance with Australian Standard AS 3959-1999 Construction of Buildings in Bushfire-Prone Areas.
The site has been identified as being in a bushfire risk area via town plan mapping. Although the town
plan does not contain construction requirements for bushfire prone areas the requirements contained in
the Building Code of Australia (BCA) Volume 2 are triggered.

Categories of bushfire attack are determined so that the appropriate vegetation separation distances and
levels of bushfire construction can be applied to the particular site/ proposed building works. Extreme
levels of attack (i.e. greater than those designated as ‘high’) are outside the scope of AS 3959-1999 and,
therefore specific design and construction requirements should be provided to meet Performance
Requirement P2.3.4 of the BCA Volume 2. For the category of ‘low’ bushfire attack, the degree of
bushfire attack is considered insufficient to warrant specific construction requirements.

2.0 Procedure

When assessing the site to determine the vegetation separation distances and level of construction
required the following AS 3959-199 Section 2 procedure was followed:

a) Determine the vegetation separation distance, type and class, as follows:
i) Identify all vegetation in each direction from the Site for a distance of 350 metres:

ii) Consult Figure 2.1 (AS3959) copy attached to determine the vegetation type which
predominates; and

iii) Select the Predominant Vegetation Class (A to F) as described in Clause 2.2.2.

b) Determine the Separation Distance between the Predominant Vegetation Class and the Site as
described in Clause 2.2.3.

 

GOLD COAST OFFICE WESTERN REGION OFFICE
PHONE 07 5578 1622 PHONE 07 4742 2022
FAX 07 5596 1294 FAX 07 4742 2033

Suite 26 “Advance POSTAL 42B Ramsay St POSTAL

Business Centre” PO Box 2760 CLONCURRY QLD 4824 — PO Box 557

39-47 Lawrence Drive NERANG QLD 4211 CLONCURRY QLD 4824

NERANG QLD 4211
Log in to download the original file

Bushfire.pdf · 883 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.