17-0022/T0070 2.4. MODELLED INFRASTRUCTURE The two inlet pits, connected by a 375mm diameter pipe, and the 450mm pipe at 0.3% grade into the canal have been modelled as part of this assessment. Refer to Figure 2 for further details. In addition, the proposed 450mm x 300mm RCBC has been included in the model. The area beside the proposed dwelling has been included, as has a section of Gympie Terrace. Refer to Figure 3 for further details. Figure 2 – Existing Drainage Infrastructure included in XPSWMM Environment. Engineering. Education Page 3