Effluent Disposal Report_compressed
Introduction
The purpose of this report is to evaluate and design a suitable on-site treatment system and disposal
area in accordance with AS 1547 – 2012, the Queensland Plumbing and Wastewater Code, the
Plumbing and Drainage Act, The Environmental Protection Act & Local Authority requirements.
The report relates exclusively to the above site and the proposed and or existing buildings shown on
the plan only. All measurements and levels shown are as accurate as possible with the information
provided these are to be used for locating the onsite effluent disposal system only.
Site Description
Weather Conditions Scattered showers
Slope 18-22%
Slope Stability To be addressed by others
Vegetation Grassed, scattered trees
Fill Nil
Flooding Nil
Watercourses Present >10m
Site exposure Sun & wind
Salinity Nil
Surface condition Nil cracks, seepage or compaction
Boulders & Rock outcrops Nil
Will water from uphill traverse the area Yes, diversion drain to prevent
Water table Nil
Soil Category (AS1547-2012 Table M1)
Borehole 0-0.1m 0.1-0.6m
BH1-BH3 Cat 4 Cat 5
Clay Loams Light Clays
Weakly Structured Moderately Structured
0.12-0.5m/d 0.06-0.12m/d
Recommended Design Irrigation Rate
Test Result 0.07
Recommended Design Irrigation Rate 3mm/day
Adopted Rate 3/mm/day
Calculations
Bedrooms 5 (5 x 1 bedroom glamping tents)
Persons 10
DIR (mm/day) 3
Litres per person per day (Tank supply) 120
Calculations 10x120=1200 /3= 400
Disposal Area Required 400m2 Heavy Droplet Surface Irrigation