C2. Eng Report
Attached to the e-mail Response to Information Request - MCU17/0572 & OPW17/0611.
Original PDF page 75, section 1. The text section number identifies this passage in the reader.
Noosa Shire Council – The Noosa Plan
Existing Services Code
Performance Criteria and Acceptable Solutions
PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES COMMENTS
Setbacks and easements S1.1 ✓
O1 The footing of any structure or building is located clear of
Development near a sewer, water main, stormwater the zone of influence but no closer than 1.5m (measured
drain, overland flow path or associated structure does horizontally) from infrastructure including sewers, water To be complied with at detailed
not— mains and stormwater structures; design / construction stages.
a) adversely affect the function of the service;
b) place an additional load on the service; and S1.2 ✓
c) unduly increase future maintenance costs. No building or structure overhangs the
zone of influence;
To be complied with at detailed
design / construction stages.
S1.3 ✓
Finished surface levels maintain a minimum of
600mm of cover, but no greater than 3m of cover to
the underground infrastructure; To be complied with at detailed
design / construction stages.
S1.4 ✓
If the existing surface level is altered, surface level
services including manholes and inspection points are
altered to match the new surface level; To be complied with at detailed
design / construction stages.
Solution: ✓ = Acceptable Solution
A/S = Alternative Solution
N/A = Not applicable to this proposal
Page 1 of 3
July 2017