d. All outdoor lights to have a maximum of 2700 K correlated colour temperature (CCT). All
indoor lights to have a maximum of 3000 K CCT. All lighting (interior and exterior) to
avoid the use of halogen, metal halide, or fluorescent lights.
e. Amber LED (590-610 nm) or low pressure sodium lighting to be used as a standard.
Warm white is to be used only where colour rendition is required. LED lights should not
contain short wavelength blue light and supplier should be asked to provide spectral
power curve of requested LEDs to prove the absence of short wavelengths.
f. The number and wattage of lights to be minimised.
g. All lights to be recessed into structures and roof, and directed away from the turtle nesting
habitat.
h. No lighting should be located on the roof of the building.
i. All outdoor lights, including balcony lights, to be turned off between 8:00 pm and sunrise
during turtle nesting and hatching season (October – May).
j. External feature lighting to the building to be positioned below 10 metres in height and
turned off between 8.00 pm and sunrise during turtle nesting and hatching season
(October – May).
k. Upward lights or vertical illumination of the building, vegetation or other structures using
lighting that shines into the sky should not be used.
l. Where lighting is required for safety purposes (including all corridors above ground level,
stairwells, entry points etc.), the lighting of these areas should be activated by proximity
sensors or motion detectors with an associated deactivation of the lighting after no more
than 10 minutes during turtle nesting and hatching season (October – May). For lighting
in other areas, timers, proximity or motion activated light sensors should be used
wherever possible.
m. Decorative outdoor lighting should not be fitted to the buildings, open space or recreation
areas (e.g. Fairy/Christmas lights) during nesting and hatching season (October – May).
n. Pool lighting to be switched off after 8:00 pm during nesting and hatching season
(October – May).
o. All exterior lighting to be shielded by a minimum of 30 cm vertical shielding.
7. PROPERTY NOTES
Not applicable.
8. VARIATION APPROVAL DETAILS
Not applicable.
9. FURTHER DEVELOPMENT PERMITS REQUIRED
Type of Development Permit Required Subject of the required Development Permit
Development Permit for Operational Works Stormwater, Earthworks, Driveway.
Development Permit for Building Works All building work.
10. SUBMISSIONS
Not applicable.
11. RIGHTS OF APPEAL
You are entitled to appeal against this decision. A copy of the relevant appeal provisions from the
Planning Act 2016 is attached.
During the appeal period, you as the applicant may suspend your appeal period and make written
representations to Council about the conditions contained within the development approval. If
Council agrees or agrees in part with the representations, a negotiated decision notice will be
issued. Only one negotiated decision notice may be given.
Page 6 of 8
Document Set ID: 22407726
Version: 3, Version Date: 04/05/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original