Appendix Q - Planning Scheme Code Responses
WASTE MANAGEMENT CODE
Performance Criteria and Acceptable Solutions
PROBABLE SOLUTIONS COUNCIL USE
PERFORMANCE CRITERIA SOLUTIONS* COMMENTS
(IF CODE ASSESSABLE) ONLY
O7 The waste storage area — criteria.
Waste storage areas are designed to (a) is bunded and graded so that
contain and appropriately dispose of washwater and bin leakage are
leakage from bins and wastewater from drained to the sewer or an on-site
bin washing. effluent disposal system via a gully
within the storage area;
(b) has a bund wall with a maximum
height of 100mm;
(c) is serviced by a conveniently located
hosecock and backflow prevention
device, and connected to a water
supply; and
(d) is roofed or otherwise covered if the
storage area is—
(i) more than 1m2; or
(ii) istoring wet waste; or
(iii) storing other waste with a high
potential to cause pollution if
washed or leaked from the bins,
including waste oil or
putrescibles.