                     Measure of                     INSIGNIFICANT   INSIGNIFICANT           MAJOR                 CATASTROPHIC
                     consequence                              5           5                     2                             1
                     RISK LEVEL                        VERY LOW      VERY LOW             VERY LOW                         LOW
                                                              VL         VL                    VL                             L
                 The small and large rotational failures through the loose sands of very low and low risk, respectively and are
                 unlikely to impact the property and people who live or spend time in the area, provided the following
                 recommendation are adhered too:

                 »     All temporary and permanent retaining walls and excavations shall be design in accordance with AS4678,
                       and stability analysis be carried out by a geotechnical engineering ensuring minimum Factors of Safety
                       (FOS) for temporary and permanent conditions of 1.3 and 1.5, respectively are achieved.
                 »     All foundations of the house to be extended to the medium dense sand, as a minimum.
                 »     The development shall adhere to good hill side practice. Examples of good and poor hill side practice for
                       the construction of residential dwelling on slopes is presented in Appendix D, Practice Note Guidelines for
                       landslide risk management 2007, from Australian Geomechanics Journal Vo 42, No. 1 dated March 2007.

                 Excavations up to 3.0 m depth could generally be designed with a safe 1.5H:1V temporary batter slope or
                 2H:1V for permanent batter slopes. This assumes that soils are not wet/saturated and groundwater is not
                 present, and is subject to the below recommendations:

                 »     All temporary batters should not have construction loads (i.e. plant, equipment or soil stockpiles) or
                       people at the crest of the batters at a distance equal to the height of the slope,
                 »     Batters should be assessed to not effect neighbouring properties/dwellings,
                 »     Permanent batters (at a minimum) should be protected from erosion. Topsoiling and planting, or erosion
                       matting should be applied to the batter as soon as possible,
                 »     Suitable drainage and stormwater provisions must be installed for the batters. Surface and stormwater
                       runover must be directed away from batters and prevented from pooling at the base and crest. At a
                       minimum, spoon drained should be installed at the crest and base of permanent batters,
                 »     Temporary batters should not remain open for extended periods of time.
                 »     Any batters or excavations exceeding this should be inspected by a suitably qualified geotechnical
                       engineer to assess to the stability of the batter, and
                 »     Batters exceeding the heights or slopes stated above, or batters that contain buildings or surcharge loads
                       within a distance equal to one batter height from the crest, should undergo detailed stability analysis to
                       determine risk levels.
                 If temporary batters steeper than 1.5H:1V are proposed for the site these will require the design of a suitable
                 retention system.

                 We trust this information is satisfactory for your current needs. Should you have any questions, please feel
                 free to contact the undersigned.

                 Regards,

                  PTG Consulting                                                                                        Reviewed By




                  Luke Goodluck                                                                                          Justin Taing
                  Branch Lead – Sunshine Coast Geotechnical                                   Regional Director – Geotechnical (RPEQ 30087)
                  p | 07 5647 0457                                                                                         p | 07 5647 0411
                  e | [email protected]                                              e | [email protected]




                 SCG Consulting Engineers                            Page 5 of 5                 SCG 0599          24 September 2025


Document Set ID: 24189920
Version: 1, Version Date: 30/09/2025
Log in to download the original file

Reference Document - MCU25 0092 & OPW25 0143 (As Published).pdf · 7.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.