Negotiated Decision Notice - 010.2007.00000256.001 [As Published] · 132007.256
2007/256
32. A minimum of 220 uncovered carpark spaces and 8 motorcycle spaces shall be provided on
site, including clearly defined disabled carpark spaces pursuant to the Building Code of
Australia (in accordance with AS2890.6).
33. The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for
User Class 3A and Class 1 for Staff spaces with allowance for vehicles to enter and leave the
site in a forward gear and with a minimum head clearance (headroom) at any point of 2.2m.
Disabled spaces will be designed in accordance with AS2890.6.
34. All carparking shall be kept, maintained and line-marked in a condition fit for use.
35. All staff carpark spaces shall be clearly defined by line marking each space with the words
“Staff Parking Only” and by sign posting each space with a similar wording.
Frontage Works
36. Footpath improvements such as topsoiling, grassing, and tree planting are required to the
street frontages of the site in accordance with Planning Scheme Policy PSP03 Landscaping
Plants & Guidelines. Grass shall be couch, free of weeds. Shade trees shall be provided
along the pathways that are constructed.
37. Any sections of the existing 3.0m wide concrete path along the Eumundi Noosa Road frontage
of the site that are damaged or made redundant due to the construction of the necessary
roadworks shall be replaced by the applicant and a new 2.0m wide concrete path shall be
constructed along the new road and Gateway Drive frontage of the site. The path works shall
be at no cost to Council, in accordance with Council’s design standards and to an alignment
that protects any significant vegetation or any underground service.
38. Pram ramps shall be installed wherever needed to direct pedestrians across the road and at
the roundabout, but the gaps in the islands shall be at road surface level and without ramps.
39. All paths, pram ramps, driveways and parking areas shall be designed and constructed to
ensure pedestrian safety using non-slip materials, to produce an evenly graded surface finish.
40. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel,
footpath paving and landscaping such as trees and grasses in accordance with Council’s
Standard specifications prior to commencement of the use permitted by this permit.
41. The developer shall provide a safe connection for pedestrians and cyclists from Eumundi
Noosa Road and Gateway Drive into the development site as shown on the approved plans of
development.
Power
42. The applicant shall be responsible for the relocation of all power services required to be
moved as a result of the works associated with this development.
Environmental Management Plan
43. An Environmental Management Plan shall be submitted to Council in conjunction with any
Operational Works application addressing:
43.1. Construction Management including:
43.1.1. Erosion and Sediment Controls;
43.1.2. Traffic Management;
43.1.3. Dust and Noise nuisance;
43.1.4. Haulage Routes.
43.2. Acid Sulfate Management; and
43.3. Operational Surface Water Management.
6 of 20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Negotiated Decision Notice - 010.2007.00000256.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 101 KB (small file)
- File type
No other editions are linked here.