O5 Within the Shire Business Centre site, as shown        S5.1 No solution provided
on Map SBC, on-site detention measures are
contained within the developed areas of the site,
clear of drainage lines and Open Space Precincts.
Run-off treatment
O6 Run-off that leaves the site is treated so as not to   S6.1 & S7.1 Development complies with the water      Bioretention areas incorporated into car park and
adversely impact on the ecology and hydrology of          quality standards in Table 2 of the SEQ Regional     landscaped areas to deal with potential contaminants
downstream environmental flows;                           Plan Implementation Guideline No. 7 for Water        before discharge to Council stormwater network.
                                                          Sensitive Urban Design.
AND
O7 Within the Shire Business Centre site, as shown
on Map SBC—
a) run-off treatment occurs within the site ; and
b) drainage lines are only used for final polishing of
run-off.


Town water supply connections
O8 Backflow devices or similar systems ensure             S8.1 A suitable backflow prevention device is        Noted – to be provided at construction
water reuse facilities have no impact on the quality of   installed to protect the potable water within the
the town mains water.                                     reticulated water supply in accordance with AS/NZS
                                                          3500:2003 Plumbing and Drainage
Use of natural treatments and systems
O9 Natural treatment strategies, including grass          S9.1 & S10.1 Development complies with the water     Bioretention areas incorporated into car park and
swales and bio-retention systems, vegetated filtration    quality standards in Table 2 of the SEQ Regional     landscaped areas to deal with potential contaminants
strips and gross pollutant traps, are used wherever       Plan Implementation Guideline No. 7 for Water        before discharge to Council stormwater network
practicable;                                              Sensitive Urban Design.

AND
O10 Within the Shire Business Centre, as shown on
Map SBC— where necessary, drainage lines are
ecologically enhanced to ensure that the water
quality polishing functions are of high standard.




                                                                                                                                       Appendix 7 – Planning Scheme Code Responses
                                                                                                                                        Material Change of Use – Industrial Use Type 2
                                                                                                                                          85 Rene Street, Noosaville – Lot 4 SP244573
Log in to download the original file

Appendix 7 - Planning Scheme CodeResponses.pdf · 169 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.