Original source · versioned page text
Appendix 7 - Planning Scheme CodeResponses
Attached to the e-mail Development Application Appendices 4,5,6 & 7 (2 of 2) MCU16/0112 & OPW16/0209.
Overall outcomes for the Water Sensitive Design Code
Overall Outcomes Response
a) all urban development has suitable treatment and reuse systems for all site Bioretention areas provided for survace stormwater treatment before discharge to
run-off; Council stotrmwater network. Roofwater collected tank for non-potable reuse
b) all urban development reduces the need for mains water by utilizing run-off Reuse of rainwater for non-potable uses.
from appropriate areas for applications such as toilet flushing and garden
maintenance;
c) pipeless stormwater management systems are utilised; Swales used where practicable.
d) downstream ecosystems, properties and infrastructure are not adversely Pollutant loads treated before leaving site.
impacted by either quantity, levels of inundation or water quality changes caused
by development; and
e) water reuse facilities have no adverse impact on the quality of the town mains No connection between reuse sources and reticulated water supply.
water.
Table 14-61 – Water Sensitive Design Code
Column 1 Column 2 Response
Specific Outcomes Probable Solutions (if code assessable)
Water reuse S3.1 Captured water is plumbed to be available for Rainwater tank with 15,000L capacity provided for
O1 Development uses a combination of detention all external uses including gardening, irrigation, non-potable reuse on-site.
and retention systems to capture run-off from areas ponds, filling swimming pools and outdoor cleaning,
on the site; as well as all ground floor toilet cisterns and washing Bioretention areas incorporated into car park and
machine cold taps; landscaped areas to deal with potential contaminants
AND before discharge to Council stormwater network.
O2 Water storage devices must have sufficient
capacity having regard to local rainfall pattern and
the catchment area of roof or other hard standing
surface;
AND AND
O3 Captured water is utilised for all non-potable uses S3.2 Where the captured water is used for toilet
on site; flushing and/or laundry use, an automatic or manual
interchange device that allows alternate use of
captured water or the reticulated water supply is
installed to ensure that there is a continual supply of
water for sanitary flushing and laundry use.
AND
O4 On-site detention does not adversely impact on S4.1 No solution provided
water requirements downstream of the site where
the water is required to sustain the ecology and
hydrology of downstream systems (environmental
flows);
Appendix 7 – Planning Scheme Code Responses