B 2
202 301
12 11 10 9 8 7 6 5 4 3
GROUND FLOOR SHOWROOM +
UPPER LEVEL COMMERCIAL
RL 18.931 FIRE
LIFT CORE STAIR 01
RL 18.305
RL 17.685 +
FIRE STAIR 02
5°
LEVEL 02
RL 16.186
RL16.900
AWNING ROOF LEVEL 01
RL13.900
GROUND FLOOR
RL8.900
REFUSE COLLECTION
PAINTED MASONRY ROLLER DOOR 01 WITH SCREENS GLAZING ROLLER DOOR 02 ROLLER DOOR 03 STAFF PARKING WINDOW HOOD ROLLER DOOR 04 PAINTED MASONRY METAL WALL CLADDING RAMP TO BASEMENT ALUMINUM TIMBER
(POWDERCOATED
(COLORBOND FINISH) (COLORBOND STEEL CLADDING OR SIMILAR) (1200mm HT CONCRETE BLOCK WALL LOOK BLADES
FRAME) PAINTED MASONRY )
PASSAGE TO
SHOWROOM
SHOPFRONT
ELEVATION Back Elevation 2
2 Scale: 1 : 100
I H G F E A
202 D C B A
METAL ROOF RL 18.931 METAL ROOF
RL 18.185
5°
3° RL 17.685 3°
RL 16.340 METAL ROOF LEVEL 02
RL 16.186 GLAZING RL16.900
5°
5° (POWDERCOATED FRAME)
COLORBOND WINDOW HOOD
GUTTER
LEVEL 01
DOWNPIPE RL13.900
CHS COLUMN
(POWDERCOATED FINISH)
GROUND FLOOR
RL8.900
METAL WIRE MESH SCREEN PAINTED MASONRY PAINTED MASONRY FOR FIRE STAIRS PAINTED MASONRY METAL WALL CLADDING
(FIXED TO WALL TO (COLORBOND STEEL CLADDING OR SIMILAR)
SUPPORT VERTICAL
VEGETATION GROWTH)
ELEVATION EASTERN Elevation
1 Scale: 1 : 100
Rev Description Date CLIENT PROJECT TITLE DRAWN BY CHECKED BY DATE
A Preliminary Issue 14.10.25 KW SM 17.11.2025
B Preliminary Issue 17.11.25
Suite 12, Level 2, 30 Florence St Proposed Commercial Centre ELEVATIONS - BACK & EASTERN ELEVATION
Teneriffe, QLD 4005 SCALE (@ A1) PROJECT NUMBER
C Draft DA Issue 18.06.26 1 : 100 25114
D DA Issue 25.06.26 [email protected] MK Architecture Pty Ltd Copyright. Except under whats allowed under copy right law, no part of this drawing may be reproduced or otherwise dealt with, without written permission of MK Architecture Pty Ltd. DRAWING NUMBER REV
E DA Issue 09.07.26 www.mkarchitecture.com.au
F DA Issue 16.07.26
Builder/Contractor shall verify job dimensions before any job commences. Figured dimensions take precedence over drawings and job dimensions. All shop drawings shall be submitted to the
Architect/Consultant, and manufacture shall not commence prior to return of inspected shop drawings by the Architect/Consultant. DA - 204 F
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2. Amended Architectural Plans (Rec 27.7.26).pdfRelated documentApplication case desk ↗
About this file
- File size
- 48.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.