shown in Figure 1. The sub-catchment areas and fraction impervious values for the catchments are tabulated
below in Table 1.

Table 1: WBNM Sub-Catchment Areas and Fraction Impervious Values

 

 

 

 

 

 

 

 

 

WBNM Sub-Catchment Area (ha) aap eC

Roof (to street) 0.009 100%

Roof 0.013 100%
Drive to Rear 0.0036 100%

North East Grass 0.007 50%
North_side 0.0059 50%
South_side 0.0065 50%

Backyard 0.0056 10%

 

 

 

 

The WBNM model has been validated with comparison of peak flows derived using the Rational Method and a
reasonable agreement was achieved. The WBNM model adopts a catchment lag parameter of 1.6, which is
within the accepted range of values provided in the WBNM technical reference manual. The rainfall loss rates
adopted for this investigation are an initial and continuing loss of Omm and 2.5mm/hr for pervious, and Omm

and Omm/hr for impervious.

Peak flows tabulated below in Table 2 represent the developed peak flow for each design storm event with the
critical duration varying from 5 to 15 minutes (5 minute for 100 year). Output summary provided in Attachment
1.

Table 2: Developed Scenario WBNM Peak Flows

 

 

 

2yr ARI Syr ARI | 10yr ARI | 20yr ARI | SOyr ARI | 100yr ARI
Catch it
ae (m*/s) | (m/s) | (m/s) | (m?/s) | (m/s) | (m°/s)
To Street 0.004 0.005 0.005 0.006 0.007 0.008
To Rear 0.019 0.023 0.026 0.029 0.033 0.037

 

 

 

 

 

 

 

 

 

Infiltration Trench Sizing

Discussion with Noosa Council (pers. Comm. Mark Lewis, 31 May 2016) indicated that the development would
need to demonstrate that runoff to the rear of the property for all but the most extreme rainfall events would
be infiltrated on-site so as not to cause scour or slope instability on adjacent properties. As such it was
determined that an infiltration trench or trenches would need to be sized to cater for the infiltration of all
design events up to and including the 1% AEP (1 in 100 year ARI design event).

m: 0439 119 890 t: +7 5414 7185

e: [email protected]
Ww: www.aquaintel.com.au

Used in these records

About this file

File size
8.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Att 3b - Stormwater.pdf · 8.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.