3,000
3,000
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
translucent balustrading glass
conc block - rendered
acrylic textured finish
boundary line
fibre cement- rendered
acrylic textured finish
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
random battens sizes & spaces
th vertical supports
conc block - rendéred 7)
acrylic textured finish
east elevation
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
fibre cement- rendered
acrylic textured finish
42 metre height line
corrugated colorbond roof sheeting
colorbond guttering & RWPS
colour TBA
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
random battens sizes & spaces
with vertical supports _UtL3 FFL 44.460
U3 FFL 43.780
FFL 43.260 u2L3
San Seas conc block - rendered
acrylic textured finish
conc jblock - rendered
acrylic textured finish
Una FFL 4.se0
FFL 40.260 U2-L2
see
FFL 37.260
Lo = = Founidary tine
{ ement walls
aaa new baserhent reinforced concrete.off form
floor level '
current level shown dotted
previously approved
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
north elevation
Douglas Street
random battens sizes & spaces
with vertical supports
conc block - rendered
14 acrylic textured finish
change E
change D
2,800
3,000
4,575
change A
proposed new basement
floor level
change E
aluminium screen to future detail
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
corrugated colorbond roof sheeting
colorbond guttering & RWPS
colour TBA
cone block - rendered
acrylic textured finish |
FeLAAA@ US
FeLAa7e0 ULL
concrete block -rendered & painted
random groove strips
FFL 40,960
Ut-L2
1
new basement -
1
:
:
i
fibre cement- rendered
acrylic textured finish
corrugated colorbond roof sheeting
colorbond guttering & RWPS
colour TBA
conc block - rendered
acrylic textured finish
concrete block -rendered & painted
random groove strips
fibre cement- rendered
acrylic textured finish
concrete block -rendered & painted
random groove strips
pa Ls al Re
L
rea) conc block - rendered
acrylic textured finish 8
|
U2L2 FFL 40,260 S Z
7)
U2-L1 FFL 37.260 5 l
Ee
wo)
5S
@)
7)
_UzloFFL93.985_\/,
columns - basement wall
reinforced concrete.off fo:
Site Control
Site control measures are to be followed to prevent erosion and sediment
export from leaving the site. A plan detailing the methods of control may be
fequired by council.
Noise emission from mechanical equipments shall comply with the local
council's Local Law No. 12.
In the instance of demolition, a waste management plan may be required by
council.
During the course of construction, property boundary fences are to be
maintained and replaced if necessary,
Energy Efficiency Requirements
§0mm Anticon insulation to be installed below roofing.
R2.5 Polywool ceiling insulation batts to be installed in roof space.
Vapour permeable RFL to all exterior framed walls.
R1.5 wall batts to all exterior framed walls.
All external Goors & windo' lo be fitted with a seal fo resrict air infilfration
and where glazed to be fitted with Pilkington ‘Evergreen’ glass.
All exhaust fans to conditioned spaces to be fitted with a self closing damper.
Hot water system shall be fitted with a heat trap within 1m of the outlet of the
heater and before the first branch.
Stormwater, Sewer and Water Supply
Roof & surface stormwater to be disposed of In accordance with council
requirements.
The site shall be connected to coucil's existing sewerage reticulating systems
and constructed in accordance with council standards & requirements.
The site shall be connected to council's existing town water supply and
constructed rainwater tanks are to be provided as per council requirements.
General Notes
¢ builder shall check and verify all dime
omissions fo the Architect.
Do not scale these drawings.
Drawings shall not be used for construction purposes until issued by the
Architect for construction.
RLis finished slab level
FLis finished floor level.
Refer to Engineering documentation for structural identification.
Refer to Hydraulic Engineer for plumbing design and layout.
Driveway cross-over and layback fo be constructed in accordance with local
Council regulations and design requirements.
Refer to Window and Door Schedule.
Smoke detectors to be installed in accordance with BCA regulations.
Waterproofing through-out to be applied as per manufacturers specification.
Trusses to be installed as per manufacturers specification.
Termite protection to be carried out in accordance with Australian Standards
and B.C.A. requirements.
All Windows & Doors to comply with relevant BCA regulations & Australian
Standards,
Balustrading installation and constructionto comply with BCA regulations and
relevant Australian Standards.
Pool fencing and gate construction and ressucitation signs to be installed to
comply with BCA regulations and relevant Australian Standards.
jons and verify all errors and
Termite Protection
The building shall be protected from subterranean termites by approved
physical and/or chemical barriers in accordance with AS3660.1. The precise
method of protection shall be determined by the owners and/or builder only
after consultation with a licensed pest control operator. This information then
shall be advised to the local government of licensed certifier prior to or at the
time of lodgement of the building permit approval.
Thereafter the owner/s shall ensure that any physical barriers are kept clear
of garden beds or soil build up, that any chemical barriers remain undisturb
and that annual inspections (plus eradication as necessary) are carried out
throughout the life of the building by a licenced pest control operator in
accordance with AS3660.1.
A 22-05-07 Details for Changes Application and
re-arrangement of poo! layout to unit 2
(refer to Decision Notice Condition 7)
CHANGE A
raising RL of basement level
CHANGE B
new front stair arrangement to unit 1
CHANGE C
additional visitor carpark
CHANGE D
new stair to side of buildings.
CHANGE E
replacement of balustrading with full
height screen
CHANGE F
new stair landing to stair from basement
CHANGE G
reduction in size of reflection ponds level 4
CHANGE H
unit 1, level 2, living room door to bifold.
; Project Designer
columns - basement walls ied iz
reinforced concrete.off form 1 ' je Y Will Franklin fs
, i [email protected]
' 1 7
[nnn nee n ten nnn dan en eee ene nnn en ene nn ne ee eee nee e nee - i Documentation
luminii to future detail os z - =
jumintui 1
Sandee ea 1 ‘ proposed new basement rele Watson
aoe aan ss floor level [email protected]
Lt. <4
Job No
JJ.61.04
Drawing No.
61.04.55 A
west elevation current level shown dotted
previously approved
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
04/5743 - Change to development application [As Published]Related documentApplication case desk ↗
About this file
- File size
- 14.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.