63 AS 1428.1—2009
900 min. 900 min. 900 min. 900 min.
900 min. 900 min. 900 min.
900 min. 900 min.
900 min.
900 min. 900 min. 900 min. 900 min.
900 min. 900 min.
900 min. 900 min.
900 min.
900 min.
900 min.
(b) Path of travel to ambulant toilets
DIMENSIONS IN MILLIMETRES
FIGURE 34 (in part) DISTANCE BETWEEN SUCCESSIVE DOORWAYS IN VESTIBULES
AND AIR LOCKS ON A PATH OF TRAVEL TO AMBULANT TOILETS
13.5 Door controls
13.5.1 General
Door controls in, or forming part of, the continuous accessible path of travel shall
comply with the requirements of this Clause.
13.5.2 Design and performance
Door handles and related hardware and accessories shall comply with the following:
(a) The door handle and related hardware shall be of the type that allows the door
to be unlocked and opened with one hand. The handle shall be such that the
hand of a person who cannot grip will not slip from the handle during the
operation of the latch.
NOTES:
1 Figure 35(A) shows an example of a suitable hinged door handle. Figure 35(B)
shows an example of a suitable door handle for sliding doors.
2 Door handles of ‘D’ lever type provide an adequate grip for people with hand
impairments.
(b) The clearance between the handle and the back plate or door face at the
centre grip section of the handle shall be not less than 35 mm and not more
than 45 mm.