AS 1428.1—2009 62
13.3.4 Power operated doors
To permit a wheelchair to turn through a door from a side-on approach, dimension
WL or WH are required on the approach side only. Where a sliding door is power
operated, for a front on approach the WL and WH dimensions do not apply.
NOTE: For location of manual controls for power operated doors, see Clause 13.5.3.
13.4 Distance between successive doorways in passages in an accessible
path of travel
The distance between doorways in vestibules, air locks and other similarly enclosed
A1
spaces shall be not less than 1450 mm. Where the doors encroach into space, the
distance shall be not less than 1450 mm plus the door leaf width, as shown in
Figure 34(a), and shall comply with Figure 31 and 32 as applicable.
The distances between doorways in vestibules and air locks on a path of travel to
ambulant toilets shall be in accordance with Figure 34(B).
1450 min. 1450 min. 1450 min.
WL WL
WL WL
(a) Continuous accessible path of travel
DIMENSIONS IN MILLIMETRES
FIGURE 34 (in part) DISTANCE BETWEEN SUCCESSIVE DOORWAYS IN VESTIBULES
AND AIR LOCKS
© Standards Australia www.standards.org.au