AS 1428.1-2009 PWD Code

of 116

Page text read automatically using OCR, there may be inaccuracies

 AS 1428.1—2009                                             68



        (b)      Lever handles shall have not less than 50 mm clearance from an adjacent
                 surface.
        (c)      Where separate taps are provided for hot and cold water, the hot water tap
                 shall be placed to the left of the cold water tap for horizontal configurations, or
                 above the cold water tap for vertical configurations.
        (d)      Where hot water is provided, the water shall be delivered through a mixing
                 spout.
        15.2.2 WC pan clearances
        WC pan clearances, including set-out, seat height and seat width shall be as shown
        in Figure 38.
A1




        NOTES:
        1     For the purpose of dimensioning, the front of the WC pan has been taken as the datum plane.
        2     The dimension of 800 ±10 mm from the front of the WC pan to the wall is a critical dimension.


                                              DIMENSIONS IN MILLIMETRES


            FIGURE 38 WATER CLOSET PAN CLEARANCES, SEAT HEIGHT AND SEAT WIDTH

        15.2.3 Seat
        A toilet seat shall be provided on accessible toilets. The toilet seat shall—
        (a)      be of the full-round type, (i.e., not open fronted) and with minimal contours to
                 the top surface;
        (b)      be securely fixed in position when in use;
        (c)      have seat fixings that create lateral stability for the seat when in use;
        (d)      be load-rated to 150 kg; and
        (e)      have a minimum luminance contrast of 30% with the background (e.g., pan,
                 wall or floor against which it is viewed).



 © Standards Australia                                                                            www.standards.org.au

Log in to download the original (AS 1428.1-2009 PWD Code.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.