Colorbond slotted gutter, fascia Colorbond Trimdek roof sheeting
to match roofing. Fix to manufacturer fixed to manufacturers specification
specification. 450 for wind category. (3° pitch.)
Selected powdercoated alum. screening
8m height line from NGL
fixed to manufacturers
specification
RP Boundary
Scyon 400 Axon cladding fixed in accordance
to manufacturers specification
Ceiling Height
1517
2550
Joinery
2100
Aluminum framed windows
to manufacturers specification.
Rendered blockwork or alike fence
Ceiling Height to engineers details 1.8m max h.
2700
Joinery
2400
Rendered brickwork veneer walls
FFL 2.82m
Aluminum framed windows to
manufacturers specification.
Existing neighboring retaining wall
Approx. finished
Ground Line.
Approx. Natural
SOUTH ELEVATION Ground Line.
Selected powdercoated alum. screening
fixed to manufacturers
specification (Timber look)
Colorbond slotted gutter, fascia 450 450 750 750 600
600 750 750 450
to match roofing. Fix to manufacturers
specification. Colorbond Trimdek roof sheeting
Selected PC alum. slat cladding Aluminum framed windows Rendered 200 series blockwork wall 400mm profile Axon cladding fixed in accordance fixed to manufacturers specification
to manufacturers spec. to manufacturers specification. to engineers details to manufacturers specification for wind category. (3° pitch. Shale Grey)
8m height line from NGL
Max. Building Height from Slab
Ceiling Height
2550
Joinery
2100
300 block column to engineers
6900
details.
Ceiling Height
2700
Joinery
2400
FFL 2.82m
Selected panel lift garage
Rendered brickwork veneer walls
doors to manufactures Approx. Finished
specification. Ground Line.
Approx. Natural
Ground Line.
EAST ELEVATION
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: J & S Payne
Revision Number Revision Description Revision Date Issued by Project Address: No. 111 Gympie Terrace, Noosaville Sheet Number:09 Project Number:16-024
A WD 1.0 Prelim 29/05/2017 B.Hunt
Climate Zone: 2
B WD 1.1 Prelim 10/08/2017 B.Hunt
Wind Category: To engineers spec.
Proposed Elevations
Phone: 0488209840
email: [email protected] Project Issue Date: 11/10/2017 Project Status: WD1.3 Scale: 1 : 100
website: www.iconbuildingdesign.com.au Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.