GENERAL INFORMATION
Roof Construction
Colorbond sheet metal to be fixed in
accordance with manufactures
specification. DP DP DP DP
All ridge capping, steps, hips valleys and
vent flashings to provide waterproofing
system. 37m2 29m2
15°
15°
Provide reflective foil backed sarking to
underside of roof sheeting. Colorbond SP SP SP SP
guttering and PVC Downpipes to be
15° 15°
connected to Stormwater systems in
accordance with the local authority.
87m2
Roof water requirements and calculations DP
are provided as a guide. Ensure a
5°
5°
qualified plumber/
hydraulics consultant reviews the SP SP
downpipe layouts prior to construction. DP
Soffit Construction
4.5mm F.C Sheeting and Painted
43m2
Waterproofing & water Resistant 3°
Materials
All wet area waterproofing is to
comply with AS3740, waterproofing 13m2 13m2
5°
5°
wet areas in residential buildings.
NCC Vol2 P3.8.1.0 SP SP
3°
10°
All waterproofing material systems
10°
components to be installed to SP
manufacturers specification. 32m2 SP UP
Instructions and material capability to 55m2
be checked prior to construction.
UP DP DP 3°
9m2
DP
DP
ROOF & DOWNPIPE LAYOUT PLAN
Roof water requirements and calculations are provided as a guide. Ensure a qualified plumber/
hydraulics consultant reviews the downpipe layouts prior to construction.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: J & S Payne
Revision Number Revision Description Revision Date Issued by Project Address: No. 111 Gympie Terrace, Noosaville Sheet Number:10 Project Number:16-024
A WD 1.0 Prelim 29/05/2017 B.Hunt
Climate Zone: 2
B WD 1.1 Prelim 10/08/2017 B.Hunt
Wind Category: To engineers spec.
Roof Plan
Phone: 0488209840
email: [email protected] Project Issue Date: 11/10/2017 Project Status: WD1.3 Scale: 1 : 100
website: www.iconbuildingdesign.com.au Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.