Original source · versioned page text
Minor Change Request (Planning Act 2016) 111 & 113 Gympie Terrace
Attached to the e-mail SUPESEDED - Change to DA - MCU16/0138.01.
Original PDF page 22, section 1. The text section number identifies this passage in the reader.
Colorbond Trimdek roof sheeting Colorbond Custom orb roof sheeting Line of roof behind wall Colorbond Custom orb roof sheeting
fixed to manufacturers specification fixed to manufacturers specification fixed to manufacturers specification
Wall framing to engineers detail.
for wind category. (3° pitch. Shale Grey) for wind category. (10° pitch. Shale Grey) for wind category. (10° pitch. )
Beam below rafter roof
raked ceiling section raked ceiling section
to engineers specification.
Rafter roof to engineers specification. Bed 1 Hallway Bath Bath Hallway Bed 1
3250 - tbc
3400 tbc
Ceiling Height
Wall framing to engineers detail.
Gyprock wall &
2550
Joinery
Floor Framing to
2100
ceiling linings.
engineers specification.
Joists to cantilever over Floor framing
brickwork where required. to engineers detail.
Floor Framing to
PVC Angle & Metal Flashing
engineers specification. H3
Ceiling Height
Kitchen cabinetry to manufacturers specification.
Treated Solid timber member
omitted for clarity Waterproof Compressed
2700
Joinery
Rendered and painted Garage Garage
2590
2400
F.C. sheeting fixed to
300mm sq. block piers manufacturers specification.
to engineers detail.
Fall
Subfloor ventilation Reinforced concrete Subfloor ventilation
in accordance with NCC Part 3.4.1 footing & slab to engineers in accordance with NCC Part 3.4.1
Volume 2 . Mechanical vented detail. Volume 2 . Mechanical vented
Boundary retaining to engineers details. Hardies Panel compressed sheet tiled
deck to manufacturers detail.
SECTION A - 04/06 Rendered 200 series blockwork Ableflex or alike with hardiflex in
Scale 1:100 walls to manufactuers specification. accoradence with relevant specifications
Refer to engineers details. Subfloor ventilation and manufaacturers specification.
in accordance with NCC Part 3.4.1 Termite protection in accoradence
Volume 2 . Mechanical vented with relevant specifications .
Flashing & capping to
builders specification. Colorbond Trimdek roof sheeting
fixed to manufacturers specification
Colorbond Custom orb roof sheeting for wind category. (3° pitch.)
fixed to manufacturers specification
for wind category. (5° pitch)
Mineral fibre
fire resistant material
between top of wall and
Floor Framing to underside of the roof
Ceiling Height
engineers specification. sheeting
Wir Bed 1
2550
Batten Raking bond beam
Joinery
2100
200 series all
Wall framing to engineers cores filled, grouted
detail. block wall.
Ceiling to builders 70mmx35mm timber studs
specification at 600mm crs
Ceiling Height
Bulkhead over
kitchen for 13mm SOUNDSHIELD
20mm gap between
2700
UNIT UNIT
Joinery
ducted AC plasterboard fixed to face
2400
Dining block wall and frame
2550 ceiling
111B 111A
Lounge 50mm mineral insulation or
glass wool with a density of
11kg/m3 positioned between
Subfloor ventilation COMMON WALL studs.
in accordance with NCC Part 3.4.1 FRL - 60/60/60
Volume 2 . Mechanical vented Scale 1 : 20 FRL rating required - 60/60/60
* Refer to engineers detail. FRL rating achieved - 240/240/240
Sound Insulation Rw + Ctr
Required for discontinuous construction = 50
Reinforced concrete Achieved 50 using NCC method.
footings to engineers
detail.
SECTION B - 04/06
Scale 1:100
Refer to engineers details.
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: J & S Payne
Revision Number Revision Description Revision Date Issued by Project Address: No. 111 Gympie Terrace, Noosaville Sheet Number: 11 Project Number:16-024
A WD 1.0 Prelim 29/05/2017 B.Hunt
Climate Zone: 2
B WD 1.1 Prelim 10/08/2017 B.Hunt
Wind Category: To engineers spec.
Sections
Phone: 0488209840
email: [email protected] Project Issue Date: 11/10/2017 Project Status: WD1.3 Scale: As indicated
website: www.iconbuildingdesign.com.au Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.