B210717 Concepts A
2
FLOOR AREAS:
3 5 1 LOWER 163.01 m²
Area 92.56 m²
4 Total 255.57 m²
18930
N
6000 2000
2118 2118 1815
FIREPLACE WALL LEGEND
EXTERNAL WALLS
- CLADDING - TO BUILDER'S SPEC.
F2115 2131STK-SGD - 90mm TIMBER STUD FRAME (UNO)
- 10mm PLASTERBOARD LINING (GENERAL)
3600
- 10mm 'WET STOP' OR EQUIV' (WET AREAS)
INTERNAL WALLS
L1506 - 70mm TIMBER STUD FRAME (UNO)
3000
STEP - 10mm PLASTERBOARD LINING (GENERAL)
4800 UP - 10mm 'WET STOP' OR EQUIV' (WET AREAS)
STEP 820
F1515
SEAT
D1809 REFER TO ENGINEERS DETAILS FOR
ST TEP
ARTICULATION JOINTS IF REQUIRED
EP
S
1130
820
CH2700mm
720cs LEGEND:
D1809
820
820fs C1 DENOTES - 75x75 SHS POST
930
D1806
11650
S DENOTES - PHOTOELECTRIC SMOKE ALARM
TO NCC VOL 2, 3.7.5 & AS 3786
3730
(MAINS POWERED & INTERCONNECTED)
3200
720cs
2200 G DENOTES - GAS BOTTLE/HWS LOCATION AS PER
2000 6300
AS 5601
D1806
3600 HW
FLOOR PLAN NOTES:
720cs
TERMITE PROTECTION IS TO BE PROVIDED IN ACCORD.
6000
D1806 F0624 WITH NCC VOL 2, 3.1.4 AND AS 3660.1.
PROVIDE A STATEMENT OF PROTECTION METHOD FROM A
6000 TERMITE MANAGEMENT PROFESSIONAL IN CONJUNCTION
WITH THESE DRAWINGS AT THE TIME OF SUBMISSION FOR
BUILDING APPLICATION APPROVAL.
3310
D0906
900
TOILET DOORS TO BE PROVIDED WITH LIFT-OFF HINGES,
OPEN OUTWARDS OR SLIDE UNLESS CLEAR SPACE OF
1.2m TO WC PAN
INSECT/SECURITY SCREENS TO WINDOWS AND DOORS
ARE AS PER BUILDERS SPECIFICATIONS UNO
820
2148PLD CONSTRUCTION IS NOT TO COMMENCE PRIOR TO FULL
APPROVAL BEING GRANTED IN WRITING BY THE CERTIFIER
AND LOCAL AUTHORITY
OPENING WINDOWS IN BEDROOMS MUST BE PROVIDED
WITH PROTECTION AS PER NCC 3.9.2.6 IF 2M OR MORE
ABOVE THE SURFACE BENEATH
TREADS, RAMPS AND LANDINGS MUST HAVE A SLIP-
RESISTANCE CLASSIFICATION NOT LESS THAN LISTED IN
NCC VOL 2 TABLE 3.9.1.4
MECHANICAL VENTILATION (mv) TO BE IN ACCORD.
WITH THE NCC VOL 2, 3.8.5, 3.8.7 & AS 1668.2
(DISCHARGE TO EXTERNAL AIR)
LOWER FLOOR PLAN INTERNAL GARAGE DOOR TO BE SEALED AS PER NCC
VOL 2, 3.12.3.3
1 : 100 GAS BOTTLE LOCATION AS PER AS5601
THESE DRAWINGS AND DESIGN ARE ISSUE DATE DRWN CHKD COMMENTS DATE
COPYRIGHT AND WILL NOT BE USED
PROJECT JOB SPECIFICATION BY BUILDER TAKES
OR REPRODUCED BY ANY MEANS,
* 19/08/2021 RW RW CONCEPT FLOOR PLANS
PROPOSED RESIDENCE PRECEDENCE OVER THESE PLANS LOWER FLOOR PLAN
WHOLLY OR PARTLY WITHOUT PRIOR A 01/09/2021 RW RW AMENDMENTS - CONCEPTS
CLIENT SALES PROJECT STATUS
WRITTEN PERMISSION FROM -
BESPOKE BUILDING DESIGN CONCEPT PLANS
Livable|Sustainable|Accessible|Desirable
CLIENT LOCATION SCALE SHEET SIZE CLASS WIND ISSUE
P: (07) 41289065 DO NOT SCALE FROM THIS DRAWING
VERIFY ALL DIMENSIONS PRIOR TO LOT 190 ON MCH1261 INDICATED A3 1a A
E: [email protected]
COMMENCEMENT OF ANY SITE WORKS
PO Box 7330, Urangan QLD 4655 9 RULES ROAD DRAWING FILE NUMBER PAGE
QBCC 1257937
AND REFER ANY DISCREPANCIES TO
BESPOKE BUILDING DESIGN POMONA, QLD B210717 3