B210717 Concepts A
2
FLOOR AREAS:
3 5 1 LOWER 163.01 m²
Area 92.56 m²
4 Total 255.57 m²
N
12240
3000 2000 2030 4200
1815 1218
WALL LEGEND
1209
1270
EXTERNAL WALLS
- CLADDING - TO BUILDER'S SPEC.
2131STK-SGD - 90mm TIMBER STUD FRAME (UNO)
- 10mm PLASTERBOARD LINING (GENERAL)
1215 - 10mm 'WET STOP' OR EQUIV' (WET AREAS)
4000
720cs
INTERNAL WALLS
L2106
- 70mm TIMBER STUD FRAME (UNO)
- 10mm PLASTERBOARD LINING (GENERAL)
- 10mm 'WET STOP' OR EQUIV' (WET AREAS)
DN
3230
0624
niche
REFER TO ENGINEERS DETAILS FOR
4700
ARTICULATION JOINTS IF REQUIRED
niche
0927
8250
3400
CH2550mm
820
820
LEGEND:
C1 DENOTES - 75x75 SHS POST
750 2700 750
720
820
niche
S DENOTES - PHOTOELECTRIC SMOKE ALARM
niche
TO NCC VOL 2, 3.7.5 & AS 3786
720 720 (MAINS POWERED & INTERCONNECTED)
3000
G DENOTES - GAS BOTTLE/HWS LOCATION AS PER
D1806
1960
HW AS 5601
FLOOR PLAN NOTES:
TERMITE PROTECTION IS TO BE PROVIDED IN ACCORD.
WITH NCC VOL 2, 3.1.4 AND AS 3660.1.
0612 0906 1815
1830 3000 4200 PROVIDE A STATEMENT OF PROTECTION METHOD FROM A
TERMITE MANAGEMENT PROFESSIONAL IN CONJUNCTION
WITH THESE DRAWINGS AT THE TIME OF SUBMISSION FOR
BUILDING APPLICATION APPROVAL.
TOILET DOORS TO BE PROVIDED WITH LIFT-OFF HINGES,
OPEN OUTWARDS OR SLIDE UNLESS CLEAR SPACE OF
1.2m TO WC PAN
INSECT/SECURITY SCREENS TO WINDOWS AND DOORS
ARE AS PER BUILDERS SPECIFICATIONS UNO
CONSTRUCTION IS NOT TO COMMENCE PRIOR TO FULL
APPROVAL BEING GRANTED IN WRITING BY THE CERTIFIER
AND LOCAL AUTHORITY
OPENING WINDOWS IN BEDROOMS MUST BE PROVIDED
WITH PROTECTION AS PER NCC 3.9.2.6 IF 2M OR MORE
ABOVE THE SURFACE BENEATH
TREADS, RAMPS AND LANDINGS MUST HAVE A SLIP-
RESISTANCE CLASSIFICATION NOT LESS THAN LISTED IN
NCC VOL 2 TABLE 3.9.1.4
MECHANICAL VENTILATION (mv) TO BE IN ACCORD.
WITH THE NCC VOL 2, 3.8.5, 3.8.7 & AS 1668.2
(DISCHARGE TO EXTERNAL AIR)
UPPER FLOOR PLAN INTERNAL GARAGE DOOR TO BE SEALED AS PER NCC
VOL 2, 3.12.3.3
1 : 100 GAS BOTTLE LOCATION AS PER AS5601
THESE DRAWINGS AND DESIGN ARE ISSUE DATE DRWN CHKD COMMENTS DATE
COPYRIGHT AND WILL NOT BE USED
PROJECT JOB SPECIFICATION BY BUILDER TAKES
OR REPRODUCED BY ANY MEANS,
* 19/08/2021 RW RW CONCEPT FLOOR PLANS
PROPOSED RESIDENCE PRECEDENCE OVER THESE PLANS UPPER FLOOR PLAN
WHOLLY OR PARTLY WITHOUT PRIOR A 01/09/2021 RW RW AMENDMENTS - CONCEPTS
CLIENT SALES PROJECT STATUS
WRITTEN PERMISSION FROM -
BESPOKE BUILDING DESIGN CONCEPT PLANS
Livable|Sustainable|Accessible|Desirable
CLIENT LOCATION SCALE SHEET SIZE CLASS WIND ISSUE
P: (07) 41289065 DO NOT SCALE FROM THIS DRAWING
VERIFY ALL DIMENSIONS PRIOR TO LOT 190 ON MCH1261 INDICATED A3 1a A
E: [email protected]
COMMENCEMENT OF ANY SITE WORKS
PO Box 7330, Urangan QLD 4655 9 RULES ROAD DRAWING FILE NUMBER PAGE
QBCC 1257937
AND REFER ANY DISCREPANCIES TO
BESPOKE BUILDING DESIGN POMONA, QLD B210717 4