Original source · versioned page text
24.007_The Peninsula_Issue A_22Feb24
drawing index
01 SITE PLAN
02 FLOOR PLAN, FLOOR FRAMING PLAN & TYPICAL SECTION
Project: NEW JETTY
Client: ANDREW & AMY PURSELL
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
Address: No. 43 THE PENINSULA, NOOSAVILLE Q 4566 0409 612 231 | [email protected]
WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721
Lot 279 ON RP856192 DRAWING NAME REV DATE
COVER SHEET A 22/02/24
A3
DESIGNER PROJECT NO
SD KUNKEL 24.007
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
41.700m 44°19'45" Projected boundary 4. All services to be located on site by contractor prior
peninsula
4.709 to construction.
from front
5. Do not scale off drawings, use figured dimensions
m
only. Any dimensions not nominated must be referred to
9
the
.867m
114°4
the Designer for confirmation. Contractor shall verify all
of revetme
dimensions on site prior to construction.
5'0
property details
"
nt wall to ce
10450
No. 43 The Peninsula
"
45'0
Noosaville QLD 4566
300°40'5
11407
159°
ntre of jetty
Noosa Shire Council
0m
0"
10604 - confirm Locality - Noosaville
5.00
Lot 279 on RP856192
at revetmen
10200
Site Area - 1004m²
Zone - Low Density Residential
t wall
Precinct - N/A
Overlays - Acid Sulphate Soils
11.868m
Existing deck - Flood Hazard Extents
9.0m x 3.5m seapen
7000
boat storage device
canal
313°32'10"
10000
49.0
12m proposed 10507 - confirm
jettys
5"
326°23'2
77°
31'1
0"
Existing revetment wall
39
176
11.868m
339° 1m
"
15'0
3.00
Pro
ject
ed b
oun
dar
y signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NORTH SDK SDK N3 ANDREW & AMY PURSELL NEW JETTY
No. 43 THE PENINSULA, NOOSAVILLE Q 4566
SITE PLAN 01
SHEETS IN SET
A 24.007
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
A 22/02/24 SDK CONSTRUCTION ISSUE Lot 279 ON RP856192 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
Page 3
Propert
Propert
aluminium framing sizes to engineers
y bound
y bound
10200 design & detail
ary
ary
1500 8700 1100 2800 2800 2800 700
1500l x 400w 1500l x 400w
400
kayak steps kayak steps
750
jetty
1500
Existing deck Existing deck
750
990
10090
200x50x3mm aluminium
floor joists @ 450mm crs max.
4000
7800
4000
9.0m x 3.5m seapen Composite decking over 2/152x62x8mm structural
10000
boat storage device 'c' channel headstocks per pile
280mm deep fascia
750
Do not fix jettys Do not fix jettys
jetty
1500
to revetment wall to revetment wall
750
400
315 dia. pvc insitu piles
Existing revetment wall 1500 8500 Existing revetment wall 900 2800 2800 2800 700 to engineers detail
10000
Joists to butt into headstocks
with site welded connection
floor plan floor framing & footing plan
1 1 : 100
2 1 : 100
notes
1. Contractor to confirm exact siting and orientation
prior to construction setout.
2. All building setout & confirmation of setbacks &
height to be carried out by a Licensed Surveyor.
Boundary line
3. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
200x50x3mm aluminium the Designer for confirmation. Contractor shall verify all
floor joists @ 450 crs max. dimensions on site prior to construction.
- composite decking over 4. Levels & services locations to be confirmed prior to
Do not fix jetty to Floor joists site welded to construction.
revetment wall headstocks to engineers detail 2/152x62x8mm structural
'c' channel headstocks per pile 5. Termite protection to be provided in accordance with
clause 3.1.4 of the BCA (QLD variation) & AS3660.1.
280mm deep composite decking Contractor to provide protection information for building
development application.
fascia to perimeter
legend
Existing revetment wall
Headstocks to piles to Denotes dimension to centre line
engineers detail
Denotes dimension to outside face
315 dia. pvc insitu piles
floor areas
to engineers details
jetty area 30.2 m²
section total area 30.2 m²
4 1 : 50 signatures
owner/s
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NORTH SDK SDK N3 ANDREW & AMY PURSELL NEW JETTY
No. 43 THE PENINSULA, NOOSAVILLE Q 4566
FLOOR PLAN, FLOOR FRAMING PLAN &
TYPICAL SECTION
02
SHEETS IN SET
A 24.007
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
A 22/02/24 SDK CONSTRUCTION ISSUE Lot 279 ON RP856192 2 As indicated
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies