Original source · versioned page text
24.007_The Peninsula_Issue A_22Feb24
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
41.700m 44°19'45" Projected boundary 4. All services to be located on site by contractor prior
peninsula
4.709 to construction.
from front
5. Do not scale off drawings, use figured dimensions
m
only. Any dimensions not nominated must be referred to
9
the
.867m
114°4
the Designer for confirmation. Contractor shall verify all
of revetme
dimensions on site prior to construction.
5'0
property details
"
nt wall to ce
10450
No. 43 The Peninsula
"
45'0
Noosaville QLD 4566
300°40'5
11407
159°
ntre of jetty
Noosa Shire Council
0m
0"
10604 - confirm Locality - Noosaville
5.00
Lot 279 on RP856192
at revetmen
10200
Site Area - 1004m²
Zone - Low Density Residential
t wall
Precinct - N/A
Overlays - Acid Sulphate Soils
11.868m
Existing deck - Flood Hazard Extents
9.0m x 3.5m seapen
7000
boat storage device
canal
313°32'10"
10000
49.0
12m proposed 10507 - confirm
jettys
5"
326°23'2
77°
31'1
0"
Existing revetment wall
39
176
11.868m
339° 1m
"
15'0
3.00
Pro
ject
ed b
oun
dar
y signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
NORTH SDK SDK N3 ANDREW & AMY PURSELL NEW JETTY
No. 43 THE PENINSULA, NOOSAVILLE Q 4566
SITE PLAN 01
SHEETS IN SET
A 24.007
SCALE
A3
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
A 22/02/24 SDK CONSTRUCTION ISSUE Lot 279 ON RP856192 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.