Date:

Inspector:
(initiats)

TODB

engineers & project managers

Inspected Item

Re-inspected
and approved:

 

25/11/2020

HG

. Prepaur inspection of GB1 and GB2 footings (unit 24-27):

«Finish placing cages to unit 27 ensuring correct top, bottom and side cover,

" Any rubble and debris fo be pulled out before pour,

« Where stop pour~ after concrete cured, break out ioose concrete overpour ready for next pour.
Vibrate all concrete, maintain cover during pour.

Photos to be sent

 

07/12/2020

HG

. Site meeting with B Paterson and S Davies of Tectonic re organics in building pad certified fill. BP said
once the wall is Stage 2 RW2 built they will return and excavate and remove the dark organic looking
fili as discussed with Geotech.

 

09/12/2020

HG

9. Prepour inspection of Stage 2 (Pod D) RW2 footing:
* Any rubble and debris to be pulled out before pour
Vibrate all concrete, maintain cover during pour, pull out rebar stakes as possible

Ok to pour

 

10/12/2020

HG

10. Prepour inspection of Stage 2 (Pod C) RW2 footing:
= Lift’chair some of the shear key vertical bars to achieve bottom cover
* Add starter bars for the return walls at end of pods
= Any rubble and debris to be pulled out before pour
"= pull out rebar stakes, as possible, during pour
Vibrate all concrete, maintain cover during pour

Ok to pour

 

10/12/2020

HG

11. Prepour inspection of Stage 2 (Pod C) RW2 footing:
= Check cover and rechair cage as required
«= Any rubble and debris to be pulled out before pour
" pull out rebar stakes, as possible, during pour
* Photos to be taken

Vibrate all concrete, maintain cover during pour

Photos to be
provided

 

28/01-
25/02/2021

HG

12. Intermittent Prepour inspections of precast panels and review of prepour photos

N/A

 

08/04/2021

HG

13. Stood precast panel inspection

ok

 

16/04/2021
21/04/2024

 

 

HG/SP.

 

14. Roof framing inspection to enable removal of precast panel props

 

 

Ok to remove
props

 

Noosa: 07 5449 9600
Sunshine Coast: 07 53293190
Mackay: 07 4840 2337

PO Box 61, Noosaville, OLD 4566, Australia

wwwitodconsulting.com

Inspection Record Page 2 of 3
. Tod Job Number: 18556
outstanding results personal service

infrastructure buildings subdivisions placemaking
Log in to download the original file

QB1910553 - STG 1 19 Ind Units - Lot 13 (#64) - QB1910553 - MISC - Form 11 Final & Supporting Certificates - 26.11.2021 KW.pdf · 10.4 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.