Appendix D Geotechnical report · MCU18/0013
Attached to the e-mail Detached House - MCU18/0013.
Project No. 304-2014 November, 2004 Page 16 TABLE 6 RETAINING WALL DESIGN PARAMETERS Material Density Earth Pressure Coefficient Long Term (kNim’) Flat Top Slope Top Slope 1V:4H__ | Drained (degrees) Ka Ko Ka Ko Compacted Fill * 19 0.41 0.58 0.46 0.76 25 Fill? 17 0.27 0.43 0.31 0.56 35 Loose Sand 17 0.33 0.50 0.37 0.66 30 Medium Dense Sand 18 0.29 0.46 0.33 0.60 33 Dense Sand 20 0.27 0.43 0.31 0.56 35 Very Dense Sand 22 0.21 0.36 0.27 0.47 40 Notes: 1. If fill is compacted against a retaining wall the actual earth pressure could exceed the vertical pressure (ie. Ka > 1.0). 2. Infers granular free draining material placed behind the retaining wall as a drainage layer. 6.5.3 Water Regime Not withstanding the absence of groundwater in all the boreholes and due to possible long term problems with blocking of gravel filters and drains and short term storm conditions that could flood the fill behind retaining walls, it is recommended that all retaining walls be designed for some water pressure distribution. A suggested water pressure distribution for retaining walls on this site would be one third height water pressure. 6.5.4 Construction Considerations A suitable temporary support system must also be determined to ensure the stability of the retaining wall during excavation for the proposed basement. It is expected that temporary ground anchors would be required to provide lateral restraint for the wall. In the long term, this lateral restraint would be provided by the basement slab floors propping the wall. It is expected that the temporary anchors would be installed in several rows, at staged intervals during the excavation of the basement. The design of number of rows, spacing of anchors and required anchor capacity, would be determined by the retaining wall designer. #F SOW SURVEYS ENGINEERING
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix D Geotechnical report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.3 MB (small file)
- File type
No other editions are linked here.