Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

Att 2_Heron Street - DA Revision 01.03.12_annotated_REDUCED

Attached to the e-mail MCU18/0204 - Response to Information Request - 6 Heron St Peregian Beach Part 2 of 2.

of 17

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file (12.2 MB): the original may take a few minutes to open or download. The page text below is quick to read.

                                                                                                                                                                                                               Rev Date     Issued Details
                                                                                                                                                                                                                   01.03.12    A   DA Ammendments
                                                                                                                                                                                                                                                                  Detailed Design

   Legend
   OC          Off form concrete
   HWD         Hardwood
   T1          Tile type 1
   T2          Tiles type 2
   PV          Photovoltaic array
   DP          Downpipe
   PB          Plasterboard
   FG          Frameless glass
   TM          Tensile material
   SS          Stainless steel
   PLY         Plywood

   Refer to Schedules For Details
   NOTE: All structural elements; including
   all slabs, columns, beams, footings and




                                                                                                                                                                                                                                            western boundary
                                              eastern boundary




   framing; to be in accordance with
   engineer's design and detail.


                                                                                                              BUILDING HEIGHT INDICATED
                                                                                                              ABOVE 8 METRE LINE.
glass balustrade beyond
                                                                                                              CONTRARY TO ANNOTATION                                                                                                                                   photovoltaic array
to comply with BCA part
3.9.2

building wall beyond,                                                                                                                                                                                                                                                  8m height limit at
does not protrude through                                                                                                                                                                                                                                              northern most
height limit                                                                                                                                                                                                                                                           extremity of building


roof terrace          RL 15 380


                                                                                                                                                                                                                                                                       HWD feature screen as
                                                                                                                                                                                                                                                                       scheduled

 awning                                                                                                                                                                                                                                                                OC



first floor           RL 12 140



                                                                                                                                                                                                                                                                       OC columns, typical
 SS supporting rods
                                                                                                                                                                                                                                                                       internal green wall
                                                                                                                                                                                                                                                                       beyond
 HWD seat
                                                                                                                                                                                                                                                                       DP as scheduled


ground floor          RL 8 360                                                   T1                                         T1

 nominal fit-out to
 ground floor tenancy
 shown                                                                                                                                                                                                                                                                 display

 HWD dry bar




                                                                                                                                                                                                                                  Key Plan
                                                                                                                                                                                                                                  Scale 1:500

                                                                 a: suite 6, 8 kingfisher drive, peregian beach, qld 4573
                                                                 p: (07) 5471 3033                                           New Commercial Building                                                           Scale 1:100 @ A3
    sparks architects                                            www.sparksarchitects.com
                                                                                                                             6 Heron St, Peregian Beach   Dave Maloney Investments Pty Ltd   046       DS      North Elevation                                 DD2.1
                                                                 sparks architects pty. ltd. abn 89 124 611 721
                                                                 qld architect's registration No. 3974                       project                      client                             job no.   drawn   drawing                                         dwg no.
Log in to download the original file

Att 2_Heron Street - DA Revision 01.03.12_annotated_REDUCED.pdf · 12.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.