                                                                                                                                                                                                                                                     Rev Date     Issued Details
                                                                                                                                                                                                                                                         01.03.12    A   DA Ammendments
                                                                                                                                                                                                                                                                                             Detailed Design

Legend
OC         Off form concrete
HWD        Hardwood
T1         Tile type 1
T2         Tiles type 2
PV         Photovoltaic array
DP         Downpipe
PB         Plasterboard
FG         Frameless glass
TM         Tensile material
SS         Stainless steel
PLY        Plywood

Refer to Schedules For Details
NOTE: All structural elements; including
all slabs, columns, beams, footings and
framing; to be in accordance with
engineer's design and detail.




                                                                                                                         southern boundary




                                                                                                                                                                                                         northern boundary
                                                                                                                                                                            BUILDING HEIGHT INDICATED
                       frameless glass
                       balustrade beyond                                                                                                                                    ABOVE 8 METRE LINE.
                                                                                                                                                                            CONTRARY TO ANNOTATION
                       building wall beyond,                                                                                                                                                                                                                                                        15o pitched roofs / 5kw
                       does not protrude through                                                                                                                                                                                                                                                    photovoltaic array
                       height limit                                                                                                                                                                                                                                                                 as scheduled

                       8m height limit at eastern
                       most extremity of building

                      roof terrace         RL 15 380



                       OC
                                                                                                                                             OC    OC
                                                                                                                                                                                                                                                                                                    HWD feature screen as
                       TM pivoting shade fin                                                                                                                                                                                                                                                        scheduled


                      first floor          RL 12 140




                                                                                                                                                   OC                                                                                                                                               OC columns, typical


                                                                                                                                                                                                                                                                                                    peregian square
                                                                                                                                                                                                                                                                                                    beyond
                      ground floor                     RL 8 360                                                                                                           T1



                       services enclosure /                                                                                                                                                                                                                                                         nominal fit-out to
                       bin wash down area in                                                                                                                                                                                                                                                        ground floor tenancy
                       accordance with local                                                                                                                                                                                                                                                        shown
                       council requirements



                       DP as scheduled




                                                                                                                                                                                                                                                                        Key Plan
                                                                                                                                                                                                                                                                        Scale 1:500

                                                                  a: suite 6, 8 kingfisher drive, peregian beach, qld 4573
                                                                  p: (07) 5471 3033                                                               New Commercial Building                                                                            Scale 1:100 @ A3
 sparks architects                                                www.sparksarchitects.com
                                                                                                                                                  6 Heron St, Peregian Beach                    Dave Maloney Investments Pty Ltd   046       DS      East Elevation                       DD2.2
                                                                  sparks architects pty. ltd. abn 89 124 611 721
                                                                  qld architect's registration No. 3974                                           project                                       client                             job no.   drawn   drawing                              dwg no.
Log in to download the original file

Att 2_Heron Street - DA Revision 01.03.12_annotated_REDUCED.pdf · 12.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.