Compiled Plans & Documents OPW18-0342 02
d) Service and utility uses,
including electricity The bushfire assessment
substations, major electrical report and bushfire
depots and water treatment
plants. management plan set out a
range of mitigation measures
both in relation to
construction items as well as
management in perpetuity to
assist the facilities to
withstand potential bushfire
attack, and ensure occupants
and staff are provided with
specific bushfire emergency
provisions to aid in early
evacuation should an ignition
occur.
Hazardous materials S6.1 Hazardous materials are Complies
O6 Public safety and the not manufactured The approved development
environment are not adversely and stored in a Bushfire does not involve the
affected by the detrimental Hazard Area.
impacts of bushfire on manufacture or bulk store of
hazardous materials hazardous chemicals.
manufactured or stored in bulk.
13.34 Siting, design and construction
O7 Uses and works including S7.1 Uses and works including Complies
building works are sited, building works are sited— The site is larger than 2,500m2
designed and constructed to— a) on lots greater than 2500m2; and development is
a) minimise the number of i) in locations of lowest hazard
people and property subject to within the lot (Figure 13.5 deliberately buffered from key
bushfire risk; and provides guidance); and fire runs by asset protection
b) maximise the protection of ii) to achieve setbacks from zones. These APZs are much
people and property during the hazardous vegetation of 1.5 greater than 1.5 times the
passage of a fire front. times the predominant mature height of the mature canopy.
canopy tree height or 10m
Not strips of vegetation are
whichever is the greater; and
iii) 10m from any retained intended to be retained, with
vegetation strips or small areas the exception of isolated
of vegetation; habitat trees which are feeding
and trees for the endangered
iv) so that the elements of the Glossy Black Cockatoo.
development least susceptible
to fire are sited closest to the
bushfire hazard;
b) on lots 2500m2 or less - to
maximise setbacks from
hazardous vegetation37
13.35 Water supply for fire fighting
O8 An adequate and S8.1 For premises not in a Complies
accessible water supply water service area— The site is connected to
is provided for fire fighting each lot has an accessible
reticulated water supply of
purposes can be accessed by dam, swimming pool or water
fire fighting appliances. tank accessible by the fire suitable fire fighting pressure
brigade that contains at least and is serviced by a range of
5000 litres of water. fire hydrants, high pressure
fire fighting hose reels,
sprinkler systems, etc.