Skip to the record
Mmm.. taste the original NoosaWatch™

Original source · versioned page text

Compiled Plans & Documents OPW18-0342 02

of 192

Page text read automatically using OCR, there may be inaccuracies

                                                               Retirement Living & Aged Care Facility
                                                                      Grasstree Court, Sunrise Beach


                                                     Irrespective of the above, the mitigation
                                                     methodologies identified by this report seek to
                                                     provide for increased resilience in addressing
                                                     matters such as built form, asset protection
                                                     zones, building and landscaping provisions,
                                                     property maintenance, access and egress and
                                                     evacuation.
                                                     The existing approval conditions require this
                                                     report including its attachments to be provided
                                                     to the local Fire Brigade for their information
                                                     purposes.
 3. Directly, indirectly and cumulatively avoids     A range of mitigation measures are
    an increase in the severity of the natural       recommended by this report to reduce the
    hazard and the potential for damage on           potential for bushfire impact, with the primary
    the site or to other properties; and             focus remaining on end-user safety.
 4. Avoids risks to public safety and the            Whilst the approved development does not
    environment from the location of hazardous       represent a hazardous facility, potentially
    materials and the release of these materials     flammable chemicals may be stored on site for
    as a result of the natural hazard; and           cleaning and other purposes. Any and all
                                                     chemicals must be stored indoors and ideally
                                                     within rooms which do not share an immediate
                                                     interface or have windows directly facing a
                                                     hazard source.
 5. Maintains or enhances natural processes          The approved development is subject to a
    and the protective function of landforms         range of vegetation management, ecological
    and vegetation that can mitigate risks           assessment and landscape concept plans
    associated with the natural hazard               which combined, seek to effectively balance
                                                     the natural features and processes associated
                                                     with the subject land and surrounding land, and
                                                     the required hazard mitigation approaches.
                                                     The measures and methodologies outlined in
                                                     this report remain cognisant of this strategic
                                                     balance noting the ecological value which
                                                     surrounds the land.

Additional SPP bushfire-related guidance material is anticipated to be released by the Department
of State Development, Manufacturing, Infrastructure and Planning in the near future however, as
this report relates to previously-approved development such forthcoming amendments to the SPP
are not relevant.

5.3         AS 3959 – Construction of Buildings in Bushfire Prone Areas
The AS3959 – Construction of Buildings in Bushfire Prone Areas specifies requirements and measures
for residential buildings constructed in bushfire prone areas. Bushfire attack levels (BALs), which form
the foundation upon which AS3959-2009 is applied, distinguish the level of attack buildings (and
occupants) may experience based on a range of factors which are analysed at Section 6 below.

A BAL is defined as ‘a means of measuring the severity of a buildings potential exposure to ember
attack, radiant heat and direct flame contact, using increments of radiant heat expressed in
kilowatts per metre squared, and the basis for establishing the requirements for construction to
improve protection of building elements from attack by bushfire’ (Standards Australia, 2011).

The level of attack buildings may experience is based on a range of factors including vegetation
typologies (fuel load), effective slope and separation distance, each of which has a significant



Status: Final                                                                                  March 2019
Project No.: 18-030                                                                               Page 23

Log in to download the original (Compiled Plans & Documents OPW18-0342 02.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.