Project Hazard_Risk Assessment Ozcare Noosa RACF 23-042024 STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads - Copy · OPW24/0118
Proposed Controls Responsible
Activity Hazards
Risk
Risk
HOC
Initial
Rating
(1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE) Person
Residual
Contact with or impact from – HIGH 5 Only manufacturer’s recommended components will be fitted, including blades, discs, etc. and they will be checked prior Site Management
flying particles and moving to starting the equipment. Contract Partner
objects
Incorrect use resulting in HIGH 5 All tolls to have OEM guards and handles attached and the tool will be inspected prior to use to ensure it can be used Site Management
injury safely. Contract Partner
Electricity HIGH 4 Tools classed as DIY use only are not permitted on site. Site Management
Contract Partner
Falling objects HIGH 5 If using portable electrical equipment at heights, measures will be taken to ensure that tools cannot be dropped onto Site Management
workers below. Contract Partner
Injury
Maintenance of Workers electrocuted / EXTREME 5 Any worker that identifies damaged wiring, the damage is to be report to Site Management Team that part of the Site Management
electrical shocked installation is to be isolated repaired or replaced then tested prior to putting back into service. Contract Partner
equipment Any visual inspection by an electrician that identifies damage or non-compliant wiring, that part of the installation is to be
isolated repaired or replace then tested prior to putting back into service.
Workers electrocuted / EXTREME 5 Any non-compliant electrical equipment is to be removed from service immediately and have an out of service tag Site Management
shocked attached. The electrical equipment is to be repaired or replaced and tested by a qualified person. Contract Partner
Electrocution HIGH 5 Portable socket outlets shall comply with the relevant requirements of AS/NZS 3190 - Approval and test specification – Site Management
Residual current devices Contract Partner
Reference AS/NZS 3190 - Approval and test specification – Residual current devices
AS/NZS 3112 – Approval and test specification – Plugs
AS/NZS 3120 -– Approval and test specification – Cord extension sockets
Review / Safety Interactions, Task Observations, SWMS Review, Weekly HSE Inspection, Monthly Audit as per Procore Inspection matrix
Monitoring
9.4 Lighting
Planning Workers electrocuted / EXTREME 4 All lights will be supplied from a final sub-circuit of the construction wiring and be provided with residual current Site Management
shocked protection to a maximum rated residual current of 30mA. Electrical Contractor
Workers electrocuted / EXTREME 4 All lights in the construction area will be protected against mechanical damage, with mechanical guard for lamps and Site Management
shocked adequate stability as per AS/NZS 3012 Electrical Contractor
Inability to see site hazards. MEDIUM 4 Lighting will be provided on site sufficient and suitable for the illumination of all common areas including stairways, Site Manager
Slips, trips and falls corridors, and passageways where persons must frequent, pass or use.
Project Hazard/Risk Assessment / Page 62 of 160
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Project Hazard_Risk Assessment Ozcare Noosa RACF 23-042024 STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads - Copy.pdfRelated documentApplication case desk ↗
About this file
- File size
- 836 KB (small file)
- File type
No other editions are linked here.