Council archive · source document
Revised Engineering Plans · MCU24/0153.01
Plans and drawings: the text below has words only, no drawings.
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
S
S
>
S
>
S
>
1-2
>
S
>
S
>
>
S
>
S
>
FLOWS FROM CATCHMENT
1-5(2) TO BE CONVEYED TO FLOWS FROM CATCHMENT G7
>
S
SW PIT ON GROUND LEVEL TO BE CONVEYED TO SW PIT
3-3 ON GROUND LEVEL
>
1-5(2)
S
>
S
CATCHMENT TABLE
CATCHMENT AREA(ha)
>
1-1 0.0061
S
1-3 4-1 0.0111
5-1 0.0023
1-5 1-2
1-3
0.0105
0.0027
S
3-3 0.0093
1-5 0.0032
2-1(2) 0.0123
5-1(2) S S S 5-1(2)
1-5(2)
0.0079
0.0100
.96
43
FLOWS FROM CATCHMENT 5-1(2)
TO BE CONVEYED TO SW PIT ON .63
43
GROUND LEVEL
2-1(2) NOTE:
EXCEPT WHERE NOTED ON PLAN AND ASSOCIATED DESIGN DRAWINGS,
ALL IN-GROUND SERVICES WITHIN THE PROPERTY BOUNDARY INCLUDING
BUT NOT LIMITED TO: STORMWATER DRAINAGE, SEWERAGE, WATER, GAS,
FLOWS FROM CATCHMENT 2-1(2) ELECTRICAL AND COMMUNICATIONS TO BE SAFELY BE DISCONNECTED,
TO BE CONVEYED TO SW PIT ON REMOVED FROM SITE AND CAPPED OFF AT SITE BOUNDARY. CONTRACTOR
GROUND LEVEL TO ARRANGE ALL NECESSARY APPLICATIONS AND PERMITS WITH THE
RELEVANT AUTHORITIES. SERVICES TO BE CAPPED IN ACCORDANCE WITH
RELEVANT SERVICE PROVIDER SPECIFICATIONS AND STANDARD DETAILS
5-1
1-1 LEGEND:
OE EXISTING OVERHEAD ELECTRICAL
W EXISTING WATER
S EXISTING SEWER
EXISTING TELSTRA PIT
W
4-1 WM EXISTING WATER METER
ADJACENT BOUNDARY
W
PROPOSED BOUNDARY
PROPOSED STORMWATER PIPE
W
PROPOSED STORMWATER PIT
W RETAINING WALL
> > > PROPOSED SWALE
W PROPOSED CONCRETE PAVEMENT
PROPOSED FOOTPATH
W
EL
PROPOSED BITUMEN PAVEMENT
AN
DA
W
ST
PROPOSED ROOF CATCHMENT STORMWATER
RE
ET
PROPOSED GROUND STORMWATER CATCHMENT
W
PROPOSED GROUND STORMWATER CATCHMENT
DISCHARGE POINT
FOR CONSTRUCTION
.53
49
---- ---- ---- ---- ---- North Point Approved Project Address Sheet Title
---- ---- ---- ---- ----
EOIN WHITMORE
51 ELANDA STREET, BALEIA STORMWATER CATCHMENT LAYOUT
N
---- ---- ---- ---- ---- 31423 03/06/2026
---- ---- ---- ---- ---- For and on behalf of RECOR Pty Ltd.
---- ---- ---- ---- ---- Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
02 03/06/26 ISSUED FOR CONSTRUCTION FP AY 1 0 1 2 3 4 5 www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE
SCALE (metres)
01 25/02/26 ISSUED FOR CONSTRUCTION DP AY 1 : 100 (FULL SIZE) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
in the revision description. 20240127 C041 02
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.