BEND
9992.465 N
9993.315 N
9988.174 N
9994.269 N
9996.480 N
9999.588 N
9999.004 N
1-1
4969.368 E
2-1
4970.918 E
4-1
4974.830 E
5-1
4985.700 E
4989.794 E
6-1
4995.277 E
7-1
4998.750 E
8-1
5000.998 E
1-2
4999.177 E
6-1
4995.277 E
10005.083 N
10005.291 N
10005.083 N
NOTES:
STRUCTURE NAME & 1. INTERNAL DRAINAGE PITS & PIPES TO
SETOUT COORDINATES BE COORDINATED WITH SUITABLE
QUALIFIED HYDRAULIC CONSULTANT.
EXISTING STRUCTURE
5m3 DETENTION TANK
5m3 DETENTION TANK
ARCO KLASSIK DRAIN
300X300 FIELD INLET
300X300 FIELD INLET
300x300 FIELD INLET
STRUCTURE DESCRIPTION
900x600 TYPE 2
900x600 TYPE 2
FIELD INLET
FIELD INLET
BEND
FINAL LOCATION OF TANK TO
BE COORDINATED BETWEEN
HYDRULIC ENGINEER AND
STRUCTURAL ENGINEER.
EXISTING SURFACE
DESIGN SURFACE
FINAL LOCATION OF TANK TO
BE COORDINATED BETWEEN
HYDRULIC ENGINEER AND
3 225mm IL 43.05
STRUCTURAL ENGINEER.
3 225mm IL 42.97
43.373
42.811
1.885
42.980
AEP10% HGL
AEP1% HGL
REFER TO NOTE 1
PIPE SIZE (mm) 150 150 225 225 225 225 225 225
PIPE CLASS & TYPE PVC PVC PVC PVC 3 PVC PVC PVC
PIPE GRADE (%) 1.63% 1.00% 1.00% 1.00% 1.00% 1.00% 1.00% 1.00%
PIPE SLOPE (1 in X) 61.4 100.0 100.0 100.0 100.0 100.0 100.0 100.0
FULL PIPE VELOCITY (m/s) 0.23 0.69 0.49 0.74 0.74 0.60 0.87 0.18
NORMAL DEPTH VELOCITY (m/s) 0.87 0.96 1.09 1.17 1.17 1.15 1.25 0.82
PIPE FLOW (cumecs) 0.004 0.012 0.020 0.026 0.026 0.024 0.035 0.007
CAPACITY FLOW (cumecs) 0.019 0.015 0.045 0.045 0.045 0.045 0.045 0.045
DATUM RL 32.000 26.000
HGL IN PIPE &
47.927
47.908
47.859
46.797
46.702
46.680
46.685
46.651
46.514
43.458
43.383
43.336
43.223
43.115
43.067
43.059
43.070
42.967
42.936
43.481
43.465
43.418
43.115
43.067
WSE IN STRUCTURE
1.191 (49.201)
2.000 (48.996)
2.133 (49.934)
4.525 (47.026)
0.186 (46.666)
2.508 (44.299)
0.758 (43.296)
2.508 (44.299)
FINISHED (& EXISTING)
49.042
0.788 48.600
2.133 48.668
1.362 47.773
0.186 43.387
2.308 45.408
1.146 43.977
0.611 43.399
44.156
2.050 45.408
SURFACE LEVEL
1.166
0.611
DEPTH OF INVERT BELOW FSL
47.851
47.812
46.600
46.535
46.535
46.411
43.248
43.202
43.202
43.100
42.900
42.831
42.811
42.788
42.788
43.398
43.358
42.900
INVERT LEVEL
21.290
25.943
36.146
42.980
45.303
CHAINAGE
0.000
2.365
8.828
0.000
3.988
2.365m 6.463m 12.462m 4.652m 10.203m 6.834m 2.323m 3.988m
LINE 1 2
FOR CONSTRUCTION
---- ---- ---- ---- ---- North Point Approved Project Address Sheet Title
---- ---- ---- ---- ----
EOIN WHITMORE
51 ELANDA STREET, BALEIA STORMWATER LONGITUDINAL SECTION
---- ---- ---- ---- ---- 31423 03/06/2026 SHEET 1
---- ---- ---- ---- ---- For and on behalf of RECOR Pty Ltd.
---- ---- ---- ---- ---- Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
02 03/06/26 ISSUED FOR CONSTRUCTION FP AY 1 0 1 2 3 4 5 www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE
SCALE (metres)
01 25/02/26 ISSUED FOR CONSTRUCTION DP AY 1 : 100 (FULL SIZE) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
in the revision description. 20240127 C042 02
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.