9999.588 N
1-3
4981.599 E
2-3
4987.296 E
3-3
4995.970 E
4-3
4998.781 E
7-1
4998.750 E
1-5
4980.533 E
2-5
4988.027 E
3-3
4995.970 E
10005.671 N
10007.357 N
10007.518 N
10001.890 N
10010.860 N
10016.829 N
10007.518 N
NOTES:
STRUCTURE NAME & 1. INTERNAL DRAINAGE PITS & PIPES TO
SETOUT COORDINATES BE COORDINATED WITH SUITABLE
QUALIFIED HYDRAULIC CONSULTANT.
20m3 RAINWATER
STRUCTURE DESCRIPTION
HARVEST TANK
900x600 TYPE 2
900x600 TYPE 2
900x600 TYPE 2
900x600 TYPE 2
900x600 TYPE 2
900x600 TYPE 2
900x600 TYPE 2
FIELD INLET
FIELD INLET
FIELD INLET
FIELD INLET
FIELD INLET
FIELD INLET
FIELD INLET
2 225mm IL 43.37
43.048
EXISTING SURFACE
DESIGN SURFACE
13.832
AEP1% HGL
REFER TO NOTE 1
AEP10% HGL
REFER TO NOTE 1
PIPE SIZE (mm) 225 225 225 225 150 150
PIPE CLASS & TYPE PVC PVC PVC PVC PVC PVC
PIPE GRADE (%) 9.93% 1.00% 1.00% 1.00% 15.00% 1.00%
PIPE SLOPE (1 in X) 10.1 100.0 100.0 100.0 6.7 100.0
FULL PIPE VELOCITY (m/s) 0.05 0.00 0.28 0.28 0.50 0.49
NORMAL DEPTH VELOCITY (m/s) 1.23 0.00 0.93 0.93 2.39 0.89
PIPE FLOW (cumecs) 0.002 0.000 0.011 0.011 0.009 0.009
CAPACITY FLOW (cumecs) 0.142 0.045 0.045 0.045 0.059 0.015
DATUM RL 32.000 27.000
HGL IN PIPE &
44.035
44.034
43.375
43.285
43.173
43.163
43.089
43.088
43.079
43.059
43.070
42.967
45.615
45.530
44.045
43.619
43.585
43.458
43.173
43.163
WSE IN STRUCTURE
1.101 (46.764)
1.050 (45.649)
1.911 (43.800)
1.940 (43.820)
1.243 (46.354)
1.912 (44.467)
1.911 (43.800)
FINISHED (& EXISTING)
45.101
1.075 44.425
1.703 44.988
1.920 44.933
1.007 43.977
46.687
1.405 45.411
1.611 44.988
SURFACE LEVEL
1.166
DEPTH OF INVERT BELOW FSL
44.000
43.350
43.375
43.285
43.077
43.013
42.993
42.970
42.811
45.444
44.006
43.499
43.377
43.077
INVERT LEVEL
10.917
17.255
19.567
21.835
-4.654
CHAINAGE
1.891
0.000
9.586
6.546m 9.026m 6.338m 2.312m 9.586m 12.249m
LINE 3 5
FOR CONSTRUCTION
---- ---- ---- ---- ---- North Point Approved Project Address Sheet Title
---- ---- ---- ---- ----
EOIN WHITMORE
51 ELANDA STREET, BALEIA STORMWATER LONGITUDINAL SECTION
---- ---- ---- ---- ---- 31423 03/06/2026 SHEET 2
---- ---- ---- ---- ---- For and on behalf of RECOR Pty Ltd.
---- ---- ---- ---- ---- Scale ENGINEERING + PROJECT MANAGEMENT Client Details Project Name Sheet Size
SUNSHINE COAST | BRISBANE | SYDNEY
02 03/06/26 ISSUED FOR CONSTRUCTION FP AY 1 0 1 2 3 4 5 www.recorconsulting.com | ABN 89 647 469 707 ARCHEND PROPOSED MULTIPLE RESIDENCE
SCALE (metres)
01 25/02/26 ISSUED FOR CONSTRUCTION DP AY 1 : 100 (FULL SIZE) COPYRIGHT © This drawing is subject to copyright in accordance with the agreement between RECOR Pty Ltd and RECOR's client. This Project Number Sheet Number Revision
Rev Date Revision Description Drawn Check DO NOT SCALE, IF IN DOUBT ASK
drawing shall only be used for this specific project. This drawing shall not be used for construction until marked as 'Issued For Construction'
in the revision description. 20240127 C042 02
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Revised Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.