7 Traffic Impact Assessment 7.1 Scope Assessment of the potential traffic impacts of the proposed development has been limited to the proposed vehicular site accesses to Gateway Drive and the adjacent existing northern Bunnings vehicular site access. Each site access has been assessed for the 10-year design horizon (2034) traffic demands under the ‘with development’ (project case) scenario. 7.2 Surveyed (2021) Traffic Volumes TTM Data conducted a traffic movement survey at both existing Bunnings customer vehicle site access on Gateway Drive from 6am to 9:30pm on Thursday 17th October 2021 and 6:30am to 9:30pm on Saturday 8th October 2021. The peak hour periods were found to be: • 8:15-9:15am and 2-3pm on the Thursday; and • 10-11am on the Saturday. The surveyed peak hour volumes are presented in Appendix C. 7.3 Background Traffic Growth Potential traffic growth on Gateway Drive is limited due to the closed catchment of industrial land that is serves. The proportion of currently vacant industrial land within the catchment to the north and east of the subject site is in the order of 5%. As such, the ultimate through traffic volumes on Gateway Drive passed the subject site can reasonably be anticipated to be approximately 5% higher than current volumes. For the purpose of this assessment it is conservatively assumed that the ultimate (2034) traffic volumes on Gateway Drive would increase by 10%. The estimated peak hour volumes at 2034 are shown in Appendix C. 7.4 Estimated Development Traffic 7.4.1 Generation The peak traffic generation of the proposed development has been estimated based on traffic generation surveys undertaken on the behalf of the NSW RMS for hardware store developments in NSW. The study indicated the following range of generation rates: • Weekday AM peak hour = 0.6 – 3.9vph / 100m2 GFA; • Weekday PM peak hour = 2.0 – 3.8vph / 100m2 GFA; • Saturday peak hour = 4.3 – 6.7vph / 100m2 GFA. Application of the highest rates in each range to the proposed development results in the estimated peak hour traffic generation summarised in Table 7.1. Site: Hardware & Trade Supplies Development – 178 Eumundi Noosa Rd, Noosaville QLD Reference: 21BRT0226
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Traffic Impact Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.