Council archive · source document
Appendix E - Traffic Impact Assessment · MCU22/0051
Very large file (10.9 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 19, section 1. The text section number identifies this passage in the reader.
8 Summary and Conclusions 8.1 Development Summary The proposed development is for a standalone Hardware and Trade Supplies building to be operated by Bunnings as a bulk trade supplies facility. The proposed building includes two levels; a lower at-grade level containing an on-site car parking area and an upper level containing a drive-through bulk trade supplies area. The upper level has an overall gross floor area of 1,861m2. Accounting for the necessary vehicle and pedestrian circulation areas, the upper level has an effective floor area of approximately 1,088m2. 8.2 Car Parking Arrangements A total of 57 spaces are proposed within the lower-level car parking area with an additional 6 parallel light vehicle loading bays within the upper level. The proposed supply satisfies the planning scheme acceptable outcome of a minimum of 22 spaces. The proposed design of the car parking area is in accordance with AS2890. 8.3 Access Arrangements Two vehicular site accesses to Gateway Drive are proposed including an entry-only access, located adjacent the sites southern boundary, and an exit-only access, located adjacent the northern boundary. Both accesses are designed and located in accordance with Council’s standards. Upgrade works on Gateway Drive are necessary for the proposed entry-only site access including extension of the existing channelised right turn lane at the existing northern Bunnings site access and extension of ‘no stopping’ zones on both sides of the road as indicated in TTM drawing number 21BRT0226-03A (Appendix B). Pedestrian and cyclist site access is proposed to be facilitated by way of a dedicated site access located immediately adjacent the sites southern boundary. 8.4 Service Vehicle Arrangements A designated service vehicle area is proposed at the rear of the building on the upper level. All service vehicles will circulate through the site in a 1-way anti-clockwise direction. The design layout of this area, the site accesses, and internal circulation roadways comply with the relevant design standards and are anticipated to be adequate for the service vehicle demands of the proposed development. 8.5 Active Transport Facilities The current public transport infrastructure is considered adequate for the development. To cater for potential demand for customer and staff cyclists a supply of two (2) parking spaces is considered reasonable. Whilst no Site: Hardware & Trade Supplies Development – 178 Eumundi Noosa Rd, Noosaville QLD Reference: 21BRT0226
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E - Traffic Impact Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.