Council archive · source document
190910 AGLA Hill Street (10), Sunshine Beach issue D · MCU18/0006.02
Attached to the e-mail Generally in Accordance Application MCU18/0006.02 - Cover email - Plans.
LOM KB (6) CAL W (3) SYZ R (2) WES WG (3)
ANDREW GOLD LANDSCAPE ARCHITECTURE
CRI ped (2) Bi CRI ped (2) Ghg
PO BOX 5220
MT GRAVATT EAST
QLD 4122
T 07 3420 0006
M 0405 389 243
E [email protected]
/ / / / / / / / / /
WES WG (2)
/
/
WES Z (4)
T15 LEGEND
T14 LOM ver (18)
/
BAN CC (4) T16
/
/
LOM KB (7) EXISTING / PROPOSED TURFED AREAS
PROPOSED 1800mm TIMBER SCREEN FENCE Refer Specification Notes
1800
1800
/
By builder
/
/
WES Z (5) PROPOSED 1800mm TIMBER SCREEN FENCE
T13 PROPOSED HARDSTAND
By builder Refer Architectural drawings
POOL (4 x 3) POOL (4 x 3)
/
/
WATER FEATURE ON BOTH SIDES OF WALL MASONRY BLOCK WORK WALL EXTENDED
X
By builder By builder By builder PROPOSED SYNTHETIC TURF
Install stack stone cladding. By builder
X
T12 Refer Specification Notes
X
/
/
X
PROPOSED BLOCK WORK WALL GATE GATE PROPOSED BLOCK WORK WALL PROPERTY BOUNDARY
To be core filled rendered and painted, To be core filled rendered and painted, As taken from Survey drawings
X X X X X X X X
Refer Engineering drawings Refer Engineering drawings
EXISTING CONTOURS
+ RL 40.73 + RL 40.73 T11 As taken from Survey drawings
CAR gla (1) 39.0 CAR gla (1)
BLOCK WORK WALL
1000 1000
Ghg Pt
To be core filled rendered and painted
WES Z (2) BAN CC (4)
RETAINING WALL
By builder, 1800mm timber screen fence on top
400
400
F. GR. L 40.5 / PROPOSED TIMBER SCREEN FENCE
F. SL. L 40.8 1800mm high, by builder
X PROPOSED POOL FENCE
By builder
LOM KB (6) LOM KB (6) EXISTING TREE - RETAINED
Refer Existing Tree Schedule
1400 1400
EXISTING TREE - REMOVED
1000
1000
Refer Existing Tree Schedule
PROPOSED SHADE / SCREEN TREES
Refer Planting Schedule
PROPOSED SHRUBS / GROUNDCOVERS
LOM ver (23) Refer Planting Schedule
LOM ver (23)
PROPOSED BIN LOCATION
As shown
T9 CLOTHESLINE
Attached to fence
T10
EXISTING SEWER
T8 As taken from Survey drawings
PROPOSED ROOFWATER LINE
PROPOSED RETAINING WALL
40.0 Refer Engineering drawings
By builder PROPOSED RETAINING WALL
GRATED STORMWATER INLET
1800mm timber screen fence on top By builder
CAS CI (1) WES Z (1) 1800mm timber screen fence on top
Refer Hydraulic Engineering drawings
GRE lan (1) GRE lan (1)
WES Z (1) CAS CI (1)
LOM ver (5) LOM ver (5)
D 10/09/19 UPDATED ARCHITECTURAL DWGS
Bi Bi C 17/07/19 AMENDMENTS AS REQUIRED
T6 T7 B 17/07/19 UPDATED ARCHITECTURAL DWGS
GRATED STORMWATER INLET GRATED STORMWATER INLET A 27/02/18 SUBMISSION TO NSC
Refer Hydraulic Engineering drawings Refer Hydraulic Engineering drawings
ISSUE DATE REASON
CRI ped (1) CRI ped (1)
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE AT
T4 THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
T1 T2 T3 INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
41.0 INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
T5 INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
GRAPHIC SCALE (m) 1:100 @A1
0 1 5
PROPOSED MULTI-UNIT DWELLING
Ca Ca
10 HILL STREET, SUNSHINE BEACH
SLIDING GATE
LANDSCAPE PLAN
Refer Architectural drawings
PROPOSED CONCRETE FOOTPATH PROPOSED DRIVEWAY CROSSOVER JOB NUMBER SHEET No. ISSUE DRAWN BY
Refer Engineering drawings and Refer Engineering drawings and 18.018 1 D AG/NB/AL
NSC Standard drawings NSC Standard drawings
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
PLANTING SCHEDULE GENERAL NOTES SOIL:
Spread turf underlay topsoil to a minimum depth of 100mm unless otherwise directed. Proposed topsoil must
A. ARCHITECTURAL WORKS INFORMATION comply with Australian Standards AS4419-2003.
The spacing of plants shown on plan have been derived as a compromise between growth rate, anticipated size, and the ability to provide a good vegetative cover within a reasonable space of time. Quantities indicated have been based on the spacing of individual plants appropriate to the
available area for the particular species used; where this available area increases (or decreases) through the course of construction, quantities may also need to increase (or decrease) to maintain the plant spacings indicated on plan. Refer to Architect's drawings for all information contained within these documents related to and nominated
as Architectural Works. This includes all hardscape items such as paving, outdoor structures/shelters, walls TURF:
and fencing. Architectural Works information contained within these documents are indicative only and not for To be fundamentally free from weeds and disease or other deleterious substances.
CODE SPECIES COMMON NAME SIZE** QUANTITY SPACING HEIGHT* WIDTH* construction or certification purposes. • On road reserve: Use "Wintergreen" (ie: Lawn Solutions Australia, contact 0432 707 950)
• Within subject site: Use "Platinum Zoysia" (ie: Lawn Solutions Australia, contact 0432 707 950)
B. CIVIL WORKS INFORMATION
Refer to Civil Engineer's drawings for all information contained within these documents related to and INSTALLATION:
TREES nominated as Civil Works. Civil Works information contained within these documents are indicative only and Turf shall be close turfed with staggered cross-joints and laid in straight lines, running perpendicular to the
ANDREW GOLD LANDSCAPE ARCHITECTURE
not for construction or certification purposes. contours.
PO BOX 5220
All joints shall be filled with an approved topdress light soil or sand and the turf shall be lightly rolled. MT GRAVATT EAST
Bi Banksia integrifolia Coast Banksia 45L 3 as shown 12 5 C. STRUCTURAL WORKS INFORMATION Finished levels shall be 3mm below surrounding surface levels to allow for future top dressing. Allowance QLD 4122
Refer to Structural Engineer's drawings for all information contained within these documents related to and should be made for shrinkage and settling.
Ca Cupaniopsis anacardioides Tuckeroo 45L 2 as shown 10 5 T 07 3420 0006
nominated as Structural Works. This includes retaining walls. Structural Works information contained within Turf shall be adequately watered once installed.
Ghg Grevillea Honey Gem Grevillea 45L 2 as shown 5 4 these documents are indicative only and not for construction or certification purposes. Ensure protection from trampling.
M 0405 389 243
E [email protected]
Pt Pandanus tectorius Screw Pine 25L 1 as shown 5 5
D. ELECTRICAL WORKS INFORMATION FERTILISER:
Refer to Electrical Engineer's drawings for all information contained within these documents related to and Fertiliser to be applied to the turf at the rates and period of time from installation as recommended by the
SCREENING SHRUBS nominated as Electrical Works. Electrical Works information contained within these documents are indicative supplier. If no starter Fertiliser supplied by the supplier, we recommend:
and not for construction or certification purposes. Dynamic Lifter Turf Starter:
http://www.yates.com.au/products/fertilising/organic-based/dynamic-lifter-turf-starter/#tbCQXOZuFJZ01z1B.97
E. HYDRAULIC WORKS INFORMATION Lawn Builder™ Seed & Turf Starter Slow Release Lawn Fertiliser:
CAL W Callistemon Wildfire Bottlebrush 200mm 3 1.8 2.5 2 Refer to Hydraulic Engineer's drawings for all information contained within these documents related to and https://www.scottsaustralia.com.au/scotts-brands/lawn-builder/lawn-builder-slow-release-lawn-fertilisers/
SYZ R Syzygium australe Resilience Lillypilly 200mm 2 1.5 3 2.5 nominated as Hydraulic Works. Hydraulic Works information contained within these documents are indicative lawn-builder-seed-turf-starter-slow-release-lawn-fertiliser/
only and not for construction or certification purposes.
SOIL WETTING AGENT:
We recommend the application of a soil wetting agent wetting agent (ie: non biodegradable detergent not
SHRUBS AND GROUNDCOVERS LANDSCAPE SPECIFICATION NOTES crystals ) to stop hydrophobia if not already in the starter fertiliser supplied with the turf, at the rates
recommended by the manufacturer:
LEVELS-GENERAL NOTES • Scotts Hydraflow Wetta Soil
Finish organic mulch surfaces 25 - 40mm below adjacent paving surfaces and/or edging. Finish lawn surfaces • Searle’s Penetraide
BAN CC Banksia spinulosa Coastal Cushion Banksia 140mm 8 1 0.5 1 flush with adjacent paving surfaces and/or edging. Ensure adequate falls in finished surface levels away from • Plant of Health Soils Soaker
CAR gla Carpobrotus glaucescens Pigface 140mm 2 1.5 0.3 3 buildings to drainage collection points (eg, field inlets, etc).
CAS CI Casuarina glauca Cousin It Prostrate Casuarina 140mm 2 1 0.3 1.5 WEEDS, PESTS DISEASE MANAGEMENT
SUBSOIL DRAINAGE - GENERAL NOTES Weeds are required to be removed by physical or chemical (Glyphosate or other herbicides) means. If
CRI ped Crinum pedunculatum Swamp Lily 200mm 6 1 2 2 Ensure adequate subsoil drainage elsewhere by installing suitable agricultural drainage systems where chemical means, as per the manufacturer recommendations. Refer to the following reference for guideline on
GRE lan Grevillea lanigera Mt Tamboritha Prostrate Grevillea 140mm 2 1 0.5 1.5 necessary, and especially in areas subjected to site excavation works including retaining walls. weeds, pest and disease management
LOM KB Lomandra Katie Belles Mat Rush 140mm 25 1 1.5 1.5 REFERENCE:
PLANTS http://thelawnguide.com.au
LOM ver Lomandra Verday Dwarf Lomandra 140mm 74 0.5 0.5 0.6
WES WG Westringia Wynyabbie Gem Native Rosemary 140mm 5 1.5 2 1.5 • NATSPEC shall apply to trees where Council requires this certification. SYNTHETIC TURF
WES Z Westringia Zenda Dwarf Rosemary 140mm 13 0.9 1 1 • Plants are to be good quality nursery stock from a NIASA Accredited nursery
• They shall be fundamentally free of pest and diseases. Install synthetic turf (Urban Turf Solutions 1800 872 268, www.urbanturfsolutions.com.au) to the location as shown on the drawings.
• After installation they shall be thoroughly watered.
PLANTING BEDS
TURF
SUBGRADE PREPARATION:
SUBGRADE PREPARATION: Cultivate subgrade surface by thoroughly ripping to a minimum depth of 150mm before spreading topsoil.
Turfed areas shall be prepared initially by removing all deleterious material
Cultivate subgrade surface by thoroughly ripping to a minimum depth of 150mm before spreading topsoil TOPSOIL:
*HEIGHT AND WIDTH: unless otherwise directed (ie: no cultivation under trees to be retained) Spread topsoil to a minimum depth of 300mm unless otherwise directed. Proposed topsoil must comply with
Australian Standards AS4419-2003.
Heights and widths as shown are at full maturation, indicative only and dependent on environmental and microclimatic factors
FERTILIZER:
A slow slow or controlled release fertiliser organic or inorganic to be incorporated generally into the imported
(or excavated/site topsoil). We recommend the following:
** PLANT CONTAINER SIZE: Inorganic Slow or Controlled Release fertilisers:
• Osmocote
• Nutricote
• Macrocote
45L 45 Litre container stock min Min. height at time of planting: 1.8m • E-Scape PRO by eCo-Enviroment
25L 25 Litre container stock min Min. height at time of planting: 1m
200mm 200mm dia minimum pot size Organic slow release:
• Dynamic Lifter
140mm 140mm dia minimum pot size
• Organic Link by Plant of Health
WETTING AGENT:
A wetting agent and/or soil ameliorant including a wetting agent is required to all mass planting beds:
MINIMUM STOCK SIZES • Scotts Hydraflow Wetta Soil
• Searle’s Penetraide Plant of Health Soils Soaker
The recommended minimum plant size relative to the container size is as follows. Should the stem calliper of height of the tree relative to
• Multipro by eCo-Enviroment
the container size be less than the figures shown, the tree should be rejected.
PLANTING:
Root ball volume Height (above container) Calliper (at 300mm) Clear trunk height As indicated on plan.
ORGANIC MULCHING:
45 litre 1.9 - 2.3 metres 30mm - 35mm 1200mm Proposed mulch must comply with Australian Standards AS4419-2012. Spread 1" Hoop Bark (ie:
75 litre 2.2 - 2.4 metres 40mm - 45mm 1400mm Greenfingers, contact 5546 1099) to a minimum depth of 100mm entirely over planting bed areas.
100 litre 2.4 metres 50mm 1500mm
IRRIGATION
200 litre 3.6 metres 60mm 1500mm
300 litre 4.2 metres 70mm 1500mm Planting plan has been designed to survive without an automatic irrigation system. Water additives and water
400 litre 5.5 metres 70mm 1500mm retention elements, along with hardy water-wise plants will ensure an irrigation system is not imperative to the
long-term maturation and survival of the proposed plants. If approved, install an automatic, fixed position, low
Palm trees NA NA 5 metres clear trunk pressure sprinkler irrigation system to all landscaped areas shown on the drawings internal to the site only, to
Noosa Shire Council approval. The irrigation shall meet the following performance requirements and as per
the manufacturers and/or installers specifications:
- Summer target application of 32mm
- Fully automatic and metered
- Recycled water use (from rainwater tanks)
- Commercial quality fittings and fixtures
- Mainlines
- Dripline system under mulch
- RPZ backflow prevent device
All design and documentation, materials supplied and work carried out should be in accordance with the
current relevant Australian Standards and best practice.
PLANT ESTABLISHMENT / CONTINUING MAINTENANCE
Allow a 12 WEEK Plant Establishment Period from Practical Completion to the satisfaction of the Landscape
Architect.
• Maintain adequate watering regime
• Remove weed growth from all mass planting beds and turfed areas D 10/09/19 UPDATED ARCHITECTURAL DWGS
• Fertilise (as per the notes above) C 17/07/19 AMENDMENTS AS REQUIRED
• Weed control (as per the notes above) B 17/07/19 UPDATED ARCHITECTURAL DWGS
• Prune planting, control pest and disease management (as per the notes above) to maintain healthy growth A 27/02/18 SUBMISSION TO NSC
• Replenish mulch material where necessary
• Replace dead / dying plant material ISSUE DATE REASON
• Reinstate stakes, ties and marker stakes where necessary
• Reinstate erosion control matting and other erosion control measures as necessary
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE AT
Continue maintenance works beyond Plant Establishment Period as required. THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
MANAGEMENT PLANS: RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
The turfed areas shall be throughly watered on the day of turf installation and then as follows at the equivalent DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
of 5l/m², including natural rainfall, or as required to maintain active healthy growth. DIMENSIONS ARE TO BE VERIFIED ON SITE.
Weeks 1-3: Twice a week
Weeks 3-12: Once a week or as necessary
If no irrigation, apply the above rates to the mass planting beds. Watering to use rainwater tanks if possible.
SPECIAL NOTE
Accord particular diligence to the following prime items:
TOPSOIL QUALITY and SUBGRADE PREPARATION as specified. PROPOSED MULTI-UNIT DWELLING
PLANT QUANTITY: Use only consistently well nurtured nursery stock from an approved supplier. Check with 10 HILL STREET, SUNSHINE BEACH
Landscape Architect where species substitutions must be made.
MAINTENANCE: Ensure a continuing maintenance program, including weed/disease, fertilising, watering (but
beware of over-watering) and replacement of ailing plant material. NOTES, SCHEDULES, & DETAILS
GUARANTEE
Failure to adequately address these items, best practice and relevant Australian Standards WILL result in a
sub-standard landscape outcome. JOB No. SHEET No. ISSUE DRAWN BY
18.018 2 D AG/AL/CP
Page 3
ANDREW GOLD LANDSCAPE ARCHITECTURE
PO BOX 5220
MT GRAVATT EAST
QLD 4122
T 07 3420 0006
M 0405 389 243
E [email protected]
NOTE: ROOTBALL IS LEVEL WITH
ADJACENT SOIL SURFACE TOP VIEW TOP VIEW
NOTE: DON'T PILE MULCH
FALL SOIL SURFACE TO ROOT BALL
AGAINST PLANT STEM
To maximize water catchment
100mm DEEP MULCH
100
As specified or as noted otherwise
HARDWOOD STAKE
(whichever is greater)
ROOT BALL Do not penetrate rootball with stake.
Stake to penetrate 200mm min into
or 250mm
Thoroughly moist and loosened
A
PROPOSED TREE
1.5A
existing subgrade.
25L / 45L container TIE
TOPSOIL BACKFILL TIES
As specified HESSIAN TIE
ROOT BALL Nailed to stake
THOROUGHLY CULTIVATE SUBGRADE STAKES
Thoroughly moist
AND LOOSEN SIDES OF PLANTING HOLE BERMED SOIL DISH
and loosened
STAKE
MULCH
B SLOW RELEASE FERTILIZER
2B 100mm deep
As specified
H
1.5 x H
UP TO 25L CONTAINER
2B or 150mm GROWING MEDIUM DOUBLE STAKE OPTION SINGLE STAKE OPTION
(whichever is greater)
CULTIVATED SUBGRADE
OVER 25L CONTAINER 1.5B
2 x ROOTBALL Ø
TYPICAL SHRUB PLANTING DETAIL TYPICAL TREE PLANTING DETAIL TYPICAL STAKING DETAIL
1 SECTION 1:10
2 SECTION 1:100
3 SECTION 1:20
ARTIFICIAL TURF ON BACKING
Refer Specification Notes
Ensure there are minimal creases
Secure artificial turf with pins, APPROX 70mm CRUSHED DUST
secure each corner then approx Spread evenly then compacted to
every 300mm. If a join is required, ensure surface is flat and hard
use synthetic grass tape. Trim to
required size.
TURF
MULCH
As specified
100mm deep
FINISHED GRADE
70
300
GROWING MEDIUM
Min 300mm deep
GROWING MEDIUM
100
Min 100mm deep
CULTIVATED SUBGRADE CULTIVATED SUBGRADE
Min 150mm deep Min 150mm deep
TYPICAL GARDEN BED DETAIL TYPICAL TURF PLANTING DETAIL SYNTHETIC TURF ON NATURAL GROUND
4 SECTION 1:10
5 SECTION 1:10
6 SECTION 1:10
D 10/09/19 UPDATED ARCHITECTURAL DWGS
C 17/07/19 AMENDMENTS AS REQUIRED
B 17/07/19 UPDATED ARCHITECTURAL DWGS
A 27/02/18 SUBMISSION TO NSC
ISSUE DATE REASON
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE AT
THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
DIMENSIONS ARE TO BE VERIFIED ON SITE.
PROPOSED MULTI-UNIT DWELLING
10 HILL STREET, SUNSHINE BEACH
NOTES, SCHEDULES, & DETAILS
JOB No. SHEET No. ISSUE DRAWN BY
18.018 3 D AG/AL/CP
Used in these records
190910 AGLA Hill Street (10), Sunshine Beach issue D.pdfRelated documentApplication case desk ↗