19. To ensure privacy is protected between adjoining properties, any windows located on the
southern elevation and within 10 metres of a habitable room window of the dwelling to the
south must either:
a. have a minimum window sill height or 1.75 metres above floor level, or
b. be fitted with translucent glazing, or
c. be fitted with a fixed external screen.
20. The upper level balconies must include fixed external screens, positioned in such a way to
obscure direct views into the habitable room windows or private open space areas of the
adjoining property. Any fixed external screen(s) must not extend more than 50% of the length
of the balcony.
Lighting Amenity
21. No flood lighting must be used on site. Any vertical illumination resulting from direct, reflected
or other incidental external lighting emanating from the site must not exceed 8 lux when
measured at any point 1.5 metres outside the boundary and at any level from ground level
upward.
Environment
22. Sediment or any other material including building materials or waste products must not be
deposited or released into the road reserve, stormwater drain or adjacent properties.
Waste Management
23. A waste storage area must be designed and maintained in accordance with Planning
Scheme Policy PSP9 Waste Management and the Noosa Plan’s Waste Management Code.
The waste storage area must be:
a. imperviously paved and correctly sized for all refuse and recycling containers;
b. bunded and graded so that wastewater and bin leakage drain to the sewer;
c. provided with a conveniently located hosecock and backflow prevention device,
connected to a water supply to service the area; and
d. roofed or otherwise covered.
Community Management Statement
24. Any proposed Community Management Statement required for the development pursuant to
the Body Corporate and Community Management Act 1997 must be submitted to Council for
endorsement at the same time as submission of the Building Format Plan (or similar) to
Council for compliance assessment.
25. Where titles are created for the units, unit 3 must be contained on a separate lot and must
be provided with separate services. Unit 3 must not be consolidated with any other unit
without the prior written consent of Council.
ENGINEERING
External Works
26. Henderson Street must be upgraded for the length of its frontage to the subject site. The
works must include widening of the existing footpath to 2 metres.
Condition 26 is imposed pursuant to s128 of the Planning Act 2016 being necessary trunk
infrastructure identified by Council’s LGIP to service the development.
Page 16 of 28
Document Set ID: 22322758
Version: 7, Version Date: 22/08/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Report - Code - Planning MCU22 0145 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 6.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.